INSTALLATION
Continued
LOCATING HEATER
This heater is designed to be mounted on
a wall.
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide
greater clearances from floor,
ceiling and joining wall.
WARNING: Never install the
heater
• in a bathroom (10,000 Btu/hr
only. 6,000 Btu/hr models are
allowed in a bathroom. Check
local codes.)
• in a recreational vehicle
• where curtains, furniture,
clothing or other flammable
objects are less than 36" from
the front, top or sides of the
heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
6" Blueflame
8" Plaque
Minimum
From
Sides Of
Heater
Left
Side
36"
Figure 4 - Mounting Clearances As
Viewed From Front of Heater
8
CEILING
36"
Minimum
Right
Side
Minimum To
Top Surface
Of Carpeting,
3"
Minimum To Top Surface
Tile Or Other
Of Carpeting, Tile Or Other
Combustible
Combustible Material
FLOOR
Material
www.desatech.com
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18" above floor
• locate heater where moving
vehicle will not hit it
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila-
tion, page 5.
For convenience and efficiency, install
heater
• where there is easy access for operation,
inspection and service
• in coldest part of room
THERMOSTAT SENSING BULB
(Thermostat Models Only)
The thermostat sensing bulb is located inside
the heater. Do not move this bulb during instal-
lation or operation of the heater.