ISC-7600/ISC-7800 Series Camera
Specifications
Specifications
Power Consumption
Power Output
1
Case Temperature
Storage Temperature
Humidity
Protection
Shock (Shipping and Storage)
Vibration (Shipping and Storage)
1
Case temperature can be verified using the camera's Temperature property within In-Sight Multi-Camera IDE,
which displays the camera's internal temperature in degrees Celsius. The internal temperature will be about 3 to 5
degrees above the camera case temperature. For more information, refer to the In-Sight
Guide. A thermal scanner can also be used to determine the camera case temperature. Additional cooling measures
are required if the case temperature cannot be kept below 50°C. Examples of such measures include: extra heat
sinking and/or air movement.
2
Lenses weighing more than 150 grams should be removed during shipment of this product or any machinery into
which it is built.
ISC-7600
ISC-7600C
ISC-7800C ISC-7801 ISC-7801C ISC-7802 ISC-7802C
ISC-7800
24VDC ±10%, 1.5A maximum
24VDC @ 750mA maximum to external light.
0°C to 50°C (32°F to 122°F).
-20°C to 80°C (-4°F to 176°F)
< 80% non-condensing
IP67 with all cables properly attached (or the provided connector plug
installed), the IP67-rated cover properly installed and the Micro SD card
cover fastened in place.
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z)
axis) 80 Gs (800m/s
and a 150 gram or lighter lens attached.
2
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @
10 Gs (10 to 500 Hz at 100m/s
150 gram or lighter lens attached.
13
2
at 11ms, half-sinusoidal) with cables or cable plugs
2
/ 15mm) with cables or cable plugs and a
®