C
1
1- Position the motor on the DOWN end limit by using the keys UP or DOWN.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run automati-
cally in the UP direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to validate the setting. The motor will run for 0.5 second in one direction, then in the
other. The operation is completed. Go to step §4.
D
1
1- Position the motor on the DOWN end limit by using the keys DOWN or UP.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run
automatically in the UP direction.
3- When the motor arrives on the UP End limit, press the key STOP.
4- If necessary adjust the position with the keys UP or DOWN.
5- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run
automatically in the DOWN direction.
6- Press 2 seconds the STOP key to validate the setting. The motor will stop, and will run for 0.5 second in one
direction, then in the other. The operation is completed. Go to step §4
After these operations, you can program the transmitter used before as a 1st control point. To
do so, see chapter §4.
4
Programming the first individual control point
This operation can only be performed from the transmitter that was used for operation 3.1b.
- Press the transmitter "PROG" Key for approximately one second.
The motor will run for 0.5 second in one direction and then in the
other. Your transmitter is now programmed to control the mo-
tor in stable mode. All the functions described in §6 are active.
5
Programming a new (individual, group or main) control point
5.1 - Open the memory of the receiver from the control transmitter:
- Press the "PROG" key of the transmitter for about 3 seconds. The
motor will run for 0.5 second in one direction and then in the other.
5.2 - Validate the operation from the new transmitter you want
to programm:
- Press the "PROG" key of the transmitter for about 1 second. The
motor will run for 0.5 second in one direction and then in the other.
- For group controls, repeat operations 5.1 and 5.2 for each motor in the group.
- For main controls, repeat operations 5.1 and 5.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 5.1 with a programmed trans-
mitter, then perform the operation 5.2 with the transmitter to be deleted.
2
2
3
3
4
5
4
2s
6
2s
1s
PROG
3s
PROG
1s
PROG
3/4