6159933730
Issue no : 14
Series : D
REVERSE ACTIVATION
K
See page 8.
TWO REVERSE MODES
L
See page 8.
Legend
L1 Mode 1: one touch reverse (default)
L2 Mode 2: Permanent reverse
BATTERY CHECK
M
See page 8.
LOW BATTERY STATUS AFTER EACH
TIGHTENING
N
See page 8.
SPEED SETTING MODULE -V2
O
See page 9.
ERROR CODES
Error
4 red flashing lights
5 red flashing lights
6 red flashing lights
16 / 112
Description
Clutch sensor error. The
tool does not start or
stops instantaneously.
Exceeding of the
maximum temperature
(70°C). The tool does
not start or stops
instantaneously.
Tool overheating. The tool
does not start or stops
instantaneously.
NETWORK CONNECTION
(FOR ELC TOOLS)
P
See page 12.
SPECIFIC COMMUNICATION LED
(FOR ELC TOOLS)
Q
See page 12.
No communication to network.
See "P" page 12.
Tool locked.
Batch complete.
Preventive maintenance.
PREVENTIVE MAINTENANCE
It is recommended to lubricate the clutch and the
gearbox every 500,000 cycles (Molykote BR2+).
ELC tools only
● Perform the maintenance of the
clutch every 500,000 cycles.
● Contact your local Desoutter
representative for the maintenance
procedure.
Validation / Action
The signal given by the clutch sensor is out of
tolerances. Check the sensor and the magnets
joined to the sensor. Check the flex is correctly
connected to the electronic board. If the fault still
appears, contact our customer service.
The temperature measured with the electronic
board is higher than 70°C. Wait for the tool
cool down. The tool can tighten again when
the temperature is lower than approximately
70°C. Decrease the tool rate. If the temperature
is lower than 70°C and the fault still appears,
contact our customer service.
The power requested is too big. Do not use
the tool as a drilling machine. If the fault still
appears, contact our customer service.
04/2014