Página 3
Amprobe’s warranty obligation is limited, at Amprobe’s option, to refund of the purchase price, free of charge repair, or replacement of a defective product . Resellers are not authorized to extend any other warranty on Amprobe’s behalf.
Página 4
CAT IV 600V CAT III 1000V K-TYPE W 30V VeHzE TEMP 750V B 750V B 1000V F 1000V F ACD-3300 IND ACDC-3400 IND ➊ Jaws for Current tests ➋ HOLD button ➌ Function selection knob ➍ Auxiliary feature buttons ➎...
permitted SAfETy INfoRMATIoN • The ACD-3300 IND and ACDC-3400 IND Digital Clamp meters conform to EN61010-1:2001; EN61010- 2-032:2002; CAT IV 600 V, CAT III 1000 V, class II and pollution deg. 2. EMC: conforms to EN61326-1. • Each instrument is EN61010-1 certified for Installation Category IV (600V). It is recommended for primary supply lines, overhead lines and cable systems.
INTRoDUCTIoN The ACD-3300 IND and ACDC-3400 IND True RMS Clamp-On meters are autoranging to 1000 ACA and 750 VAC / 1000 VDC. Their features include AC / DC voltage, AC / DC current (ACDC-3400 IND), Frequency, Duty Cycle, Diode, Resistance, Capacitance, Continuity tests plus Relative (ACDC-3400 IND).
ZERo (Relative) Measurements (ACDC-3400 IND only) The Relative mode displays the difference between the actual reading and a reference value. It may be used with any function or range. To make a relative measurement first establish a reference value by measuring a value and then pressing the button after the reading has stabilized.
Diode Testing (See fig. 5) Set the Function knob to the “ “ position. Use the ‘Ω’ button to select diode test (ACD-3300 IND only). Connect the red test lead to the “V Ω” jack and the black test lead to the “COM”...
Reverse probes. If the diode is good, “OL” is displayed. If the diode is shorted, “0.00” or another number is displayed. If the diode is open, “OL” is displayed in both directions. Audible Indication: Less than 30 Ω. Temperature Measurement (ACD 3300 IND only) (See fig. 6) Verify the location being tested is not electrically energized.
Battery life: typically 75 hours with carbon-zinc; 150 hour with alkaline. Dimensions: ACDC-3400 IND: 281 x 108 x 53 mm (11.1 x 4.3 x 2.1 in.) ACD-3300 IND: 279 x 103 x 53 mm (11 x 4.1 x 2.1 in.) Weight: ACDC-3400 IND: 559 gm ( 1.23 lb.) ACD-3300 IND: 500 gm ( 1.10 lb.)
Accuracy 66.00A*, 660.0A,1000A 50 to 400 Hz ± (3.0% rdg + 200 dgts) * ACD-3300 IND only ** Frequency: 10% to 100% of current range AC coupled TRMS: 5% to 100% of range Crest factor: ≤ 3 Overload protection: 1000A AC...
Página 15
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 2. Voltage \ Frequency \ Duty Cycle HOLD 1000A 660A 1000 A 600 A Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V...
Página 16
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE µ F CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 4. Capacitance HOLD 1000A 660A Δ ZERO PEAK ± MAX/MIN RANGE kΩ CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F...
Página 17
1000 1832 ºC 1000 ºF ºF PEAK ± MAX/MIN RANGE Cal > 2 sec RANGE °F CAT IV 600V CAT III 1000V K-TYPE W 30V TEMP 750V B 1000V F Fig 6. Temperature (ACD-3300 IND only) Fig 7. Battery Replacement...
Les appareils européens non couverts par la garantie peuvent être remplacés par votre distributeur Amprobe ® Test Tools pour une somme nominale. Consultez la section « Where to Buy » sur le site www.amprobe.com pour obtenir la liste des distributeurs dans votre région. Adresse postale européenne* Amprobe ®...
Página 20
CAT III 1000V K-TYPE W 30V VeHzE TEMP 750V B 750V B 1000V F 1000V F ACD-3300 IND ACDC-3400 IND ➊ Mâchoires pour tests de courant ➋ Bouton de maintien HOLD ➌ Sélecteur de fonction ➍ Boutons de fonctions auxiliaires ➎...
Página 21
Pinces multimètres industrielles CAT IV ACD-3300 IND/ACDC-3400 IND TRMS Symboles ..........................21 Consignes de sécurité ......................21 Mises en garde et précautions ................. 21 Déballage et vérification du contenu ................22 Introduction ......................... 22 Fonctions Auxiliaires ......................22 Bouton poussoir PEAK+/- ....................22 Bouton MAX/MIN ......................
CoNSIgNES DE SéCURITé • Les pinces multimètres numériques modèles ACD-3300 IND et ACDC-3400 IND sont compatibles avec EN61010-1:2001 ; EN610102-032:2002 ; CAT IV 600 V, CAT III 1000 V, classe II et degré de pollution 2. EMC: conforms to EN61326-1.
INTRoDUCTIoN Les modèles ACD-3300 IND et ACDC-3400 IND sont des pinces multimètres TRMS de 1000 A c.a. et de 750 V c.a./1000 V c.c. Ils proposent les fonctions de mesure suivantes : tension c.a./c.c., courant c.a./c.c.
Mesure ZERo (relative) (ACDC-3400 IND uniquement) Le mode relatif affiche la différence entre la valeur réelle et la valeur de référence. Il peut être utilisé avec toutes les fonctions ou gammes. Pour effectuer une mesure relative, établissez la valeur de référence en mesurant une valeur et en appuyant sur le bouton ...
1. Réglez le sélecteur de fonction sur la position « ». Utilisez le bouton « Ω » pour sélectionner le contrôle de diode (ACD-3300 IND uniquement). 2. Reliez le cordon de mesure rouge à la prise « VΩ » et le cordon de mesure noir à la prise «...
4. Touchez la diode avec les sondes. Une baisse de tension directe est d’environ 0,6 V (typique pour une diode au silicium). 5. Inversez les sondes. Si la diode est bonne, « OL » apparaît. Si la diode est en court- circuit, «...
Página 27
Dimensions : ACDC-3400 IND : 283 x 105 x 50 mm (11,1 x 4 x 2,1 po) ACD-3300 IND : 283 x 105 x 50 mm (11 x 4 x 2,1 po) Poids : ACDC-3400 IND : 559 gm (1,23 lb) ACD-3300 IND : 500 gm (1,10 lb) Sécurité...
Página 28
50 à 400 Hz ± (3,0 % de lecture + 200 chiffres) * ACD-3300 IND uniquement ** Fréquence : de 10 % à 100 % de la gamme de courant Mesure eff. vraie couplée en c.a. : de 5 % à 100 % de la gamme Facteur de crête : ≤...
Página 29
± (3,0 % de lecture + 10 chiffres) 6,6 mF ± (5,0 % de lecture + 10 chiffres) Protection contre les surcharges : 1000 V c.c. ou 750 V c.a. eff. TEMPERATURE (ACD-3300 IND uniquement) gamme Précision 0,0 °C à 400,0 °C ±...
CONTROLE DE DIODE Courant de test : 0,8 mA (approximatif) Précision : ± (1,5 % de lecture + 5 chiffres) Volts en circuit ouvert : 3,2 V c.c. typique Indication sonore : < 0,03 V Protection contre les surcharges : 1000 V c.c. ou 750 V c.a. eff. CONTINUITE Gammes : 660,0 Ω...
Página 31
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 2. Tension \ Fréquence \ Rapport cyclique HOLD 1000A 660A 1000 A 600 A Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V...
Página 32
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE µ F CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 4. Capacité HOLD 1000A 660A Δ ZERO PEAK ± MAX/MIN RANGE kΩ CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F...
Página 33
1832 ºC 1000 ºF ºF PEAK ± MAX/MIN RANGE Cal > 2 sec RANGE °F CAT IV 600V CAT III 1000V K-TYPE W 30V TEMP 750V B 1000V F Fig 6. Température (ACD-3300 IND uniquement) Fig 7. Changement des piles...
Haftungsbeschränkung Es wird gewährleistet, dass dieses Amprobe-Produkt für die Dauer von einem Jahr ab dem Kaufdatum frei von Material- und Fertigungsdefekten ist. Diese Gewährleistung erstreckt sich nicht auf Sicherungen, Einwegbatterien oder Schäden durch Unfälle, Nachlässigkeit, Missbrauch, Änderungen oder abnormale Betriebsbedingungen bzw.
Página 36
CAT III 1000V CAT IV 600V CAT III 1000V K-TYPE W 30V VeHzE TEMP 750V B 750V B 1000V F 1000V F ACD-3300 IND ACDC-3400 IND ➊ Backen für Stromprüfungen ➋ HOLD-Taste ➌ Drehschalter für Funktionsauswahl ➍ Hilfsfunktionstasten ➎ A Primäre LCD-Anzeige ➎...
Página 37
ACD-3300 IND / ACDC-3400 IND CAT IV Industrielle Echteffektivwert-Zangenmessgeräte Symbole ..........................37 Sicherheitsinformationen ....................37 Warn- und Vorsichtshinweise .................. 37 Auspacken und Inhalt ......................38 Einleitung ..........................38 Zusätzliche Funktionen ....................... 38 PEAK+/--Taste ......................... 38 MAX/MIN-Taste ......................38 ZERO, Relativ-Messungen (nur ACDC-3400 IND) ............. 39 HOLD-Taste ........................
Leitern zulässig. SICHERHEITSINfoRMATIoNEN • Die digitalen Zangenmessgeräte ACD-3300 IND und ACDC-3400 IND stimmen überein mit EN61010-1:2001; EN61010- 2-032:2002; CAT IV 600 V, CAT III 1000 V, Klasse II und Verschmutzungsgrad 2. EMC: conforms to EN61326-1. • Diese Messgeräte sind EN61010-1-zertifiziert für Installationskategorie IV (600 V).
über automatische Bereichseinstellung bis 1000 ACA und 750 VAC / 1000 VDC. Zu den Funktionen gehören Wechselspannung/Gleichspannung, Wechselstrom/Gleichstrom (ACDC-3400 IND), Frequenz, Tastgrad, Dioden-, Widerstands-, Kapazitäts-, Kontinuitätsprüfungen plus Relativmodus (ACDC-3400 IND). Das Modell ACD-3300 IND misst zudem Temperatur bis 1000 °C (1832 °F). ZUSäTZLICHE fUNkTIoNEN PEAk+/--Taste Wird verwendet, um die Spitzenwerte Peak+ und Peak- für Wechselspannungs- und...
ZERo, Relativ-Messungen (nur ACDC-3400 IND) Der Relativ-Modus zeigt den Unterschied zwischen der tatsächlichen Messung und einem Referenzwert an. Dieser Modus kann mit jeder Funktion oder jedem Bereich verwendet werden. Zur Durchführung relativer Messungen einen Referenzwert erstellen, indem ein Wert gemessen und dann die -Taste gedrückt wird, nachdem sich die Messanzeige stabilisiert hat.
Widerstandsmessung (siehe Abb. 5) 1. Den Funktionsschalter auf Ω stellen. Die Taste Ω verwenden, um die Widerstandsprüfung auszuwählen (nur ACD-3300 IND). 2. Die Messleitungen anschließen: Rot an +, Schwarz an CoM. 3. Die Stromversorgung des zu messenden Schaltkreises ausschalten. Strom niemals über eine Spannungsquelle oder in einem stromführenden Stromkreis messen.
Diodenprüfung (siehe Abb. 5) 1. Den Funktionsdrehschalter auf die Position einstellen. Die Taste Ω verwenden, um Diodenprüfung auszuwählen (nur ACD-3300 IND). 2. Die rote Messleitung an die VΩ-Buchse anschließen und die schwarze Messleitung an die COM-Buchse anschließen. 3. Die Stromversorgung des zu prüfenden Stromkreises ausschalten. Externe Spannung über den Komponenten verursacht ungültige Messwerte.
Batterielebensdauer: typisch 75 Stunden mit Kohlezink-Batterie; 150 Stunden mit Alkalibatterie Abmessungen: ACDC-3400 IND: 281 x 108 x 53 mm ACD-3300 IND: 279 x 103 x 53 mm Gewicht: ACDC-3400 IND: 559 g ACD-3300 IND: 500 g Sicherheit: LVD erfüllt EN61010-1:2001 und EN61010-2-032:2002, CAT III 1000 V, CAT IV 600 V, Klasse II und Verschmutzungsgrad 2 ...
Página 44
66,00 A*, 660,0 A, 1000 A 50 bis 400 Hz ± (3,0 % Anzeige + 200 Stellen) * Nur ACD-3300 IND ** Frequenz: 10 % bis 100 % von Strombereich TRMS wechselstromgekoppelt: 5 % bis 100 % von Bereich Spitzenfaktor: ≤ 3...
Página 45
± (3,0 % Anzeige + 10 Stellen) 6,6 mF ± (5,0 % Anzeige + 10 Stellen) Überlastschutz: 1000 VDC oder 750 VAC eff. TEMPERATUR (nur ACD-3300 IND) bereich genauigkeit 0,0 °C bis 400,0 °C ± (1,0 % + 1 °C) -35,0 °C bis 0,0 °C, 400 °C bis 1000 °C...
Página 46
DIODENPRÜFUNG Prüfstrom: 0,8 mA (ca.) Genauigkeit: ± (1,5 % Anzeige + 5 Stellen) Spannung in unterbrochenen Schaltkreisen: 3,2 VDC typisch Akustische Anzeige: < 0,03 V Überlastschutz: 1000 VDC oder 750 VAC eff. KONTINUITÄT Bereiche: 660,0 Ω Akustische Anzeige: < 30 Ω Ansprechzeit: 500 ms Überlastschutz: 1000 VDC oder 750 VAC eff.
Página 47
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Abb. 2. Spannung \ Frequenz \ Tastgrad HOLD 1000A 660A 1000 A 600 A Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V CAT III 1000V...
Página 48
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE µ F CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Abb. 4. Kapazität HOLD 1000A 660A Δ ZERO PEAK ± MAX/MIN RANGE kΩ CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F...
Página 49
1832 ºC 1000 ºF ºF PEAK ± MAX/MIN RANGE Cal > 2 sec RANGE °F CAT IV 600V CAT III 1000V K-TYPE W 30V TEMP 750V B 1000V F Abb. 6. Temperatur (nur ACD-3300 IND) Abb. 7. Auswechseln der Batterie...
Questo prodotto Amprobe sarà esente da difetti di materiale e fabbricazione per un anno a decorrere dalla data di acquisto. Sono esclusi da questa garanzia i fusibili, le pile monouso e i danni causati da incidenti, negligenza, uso improprio, alterazione, contaminazione o condizioni anomale di funzionamento o maneggiamento.
Página 52
CAT IV 600V CAT III 1000V K-TYPE W 30V VeHzE TEMP 750V B 750V B 1000V F 1000V F ACD-3300 IND ACDC-3400 IND ➊ Ganasce per le misure di corrente ➋ Pulsante HOLD ➌ Selettore funzioni ➍ Pulsanti funzioni ausiliarie ➎...
Página 53
ACD-3300 IND / ACDC-3400 IND Pinze amperometriche industriali a vero valore efficace CAT IV Simboli ..........................53 Informazioni sulla sicurezza ....................53 Avvertenze e precauzioni ..................53 Disimballaggio e contenuto ....................54 Introduzione ........................54 Funzioni Ausiliarie ....................... 54 Pulsante PEAK+/- ......................
INfoRMAZIoNI SULLA SICUREZZA • Le pinze amperometriche digitali ACD-3300 IND e ACDC-3400 IND sono a norma EN61010-1:2001; EN61010- 2-032:2002; CAT IV 600 V, CAT III 1000 V, classe II e livello di inquinamento 2. EMC: conforms to EN61326-1.
INTRoDUZIoNE Le pinze amperometriche a vero valore efficace ACD-3300 IND e ACDC-3400 IND sono strumenti a selezione automatica della portata sino a 1000 A c.a. e 750 V c.a. / 1000 V c.c.
questa modalità tenere premuto il pulsante MAX/MIN per almeno 2 secondi. Misure (relative) con AZZERAMENTo (solo per il modello ACDC-3400 IND) La modalità di misura relativa visualizza la differenza tra la lettura attuale e un valore di riferimento, ed è utilizzabile con qualsiasi funzione o portata. Per eseguire una misura relativa, stabilire anzitutto un valore di riferimento eseguendo una misura e poi premendo il pulsante ...
1. Portare il selettore funzioni nella posizione . Usare il pulsante ‘Ω’ per selezionare la funzione prove di continuità (solo per il modello ACD-3300 IND). 2. Collegare i cavi di misura: quello rosso al terminale +, quello nero al terminale CoM.
1. Portare il selettore funzioni nella posizione “ ”. Usare il pulsante ‘Ω’ per selezionare la funzione prove di diodi (solo per il modello ACD-3300 IND). 2. Collegare il cavo di misura rosso al terminale “VΩ” e quello nero al terminale “COM”.
Alimentazione: una pila standard da 9 V, NEDA 1604, JIS 006P, IEC 6F22 Autonomia: tipicamente 75 ore con pila al carbonio-zinco; 150 ore con pila alcalina Dimensioni ACDC-3400 IND: 281 x 108 x 53 mm ACD-3300 IND: 279 x 103 x 53 mm Peso: ACDC-3400 IND: 559 g ACD-3300 IND: 500 g Sicurezza: direttira sulle basse tensioni;...
Página 60
Da 50 a 400 Hz ± (3,0% della lettura + 200 cifre) * Solo per il modello ACD-3300 IND ** Frequenza: dal 10% al 100% della portata di corrente Vero valore efficace con accoppiamento c.a.: dal 5% al 100% della portata Fattore di cresta: ≤...
± (3,0% della lettura + 10 cifre) 6,6 mF ± (5,0% della lettura + 10 cifre) Protezione dai sovraccarichi: 1000 V c.c. o 750 V c.a. rms MISURE DI TEMPERATURA (solo per il modello ACD-3300 IND) Portata Precisione Da 0,0 °C a 400,0 °C ±...
PROVE DI DIODI Corrente di prova: 0,8 mA (approssimata) Precisione: ± (1,5% della lettura + 5 cifre) Tensione di circuito aperto: 3,2 V c.c. tipica Segnalazione acustica: < 0,03 V Protezione dai sovraccarichi: 1000 V c.c. o 750 V c.a. rms PROVE DI CONTINUITÀ...
Página 63
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 2. Misure di tensione \ frequenza \ duty cycle HOLD 1000A 660A 1000 A 600 A Δ ZERO PEAK ±...
Página 64
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE µ F CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 4. Misure di capacità HOLD 1000A 660A Δ ZERO PEAK ± MAX/MIN RANGE kΩ CAT IV 600V CAT III 1000V VeHzE 750V B...
Página 65
PEAK ± MAX/MIN RANGE Cal > 2 sec RANGE °F CAT IV 600V CAT III 1000V K-TYPE W 30V TEMP 750V B 1000V F Fig 6. Misure di temperatura (solo per il modello ACD-3300 IND) Fig 7. Sostituzione della pila...
Su producto Amprobe estará libre de defectos de material y mano de obra durante 1 año a partir de la fecha de adquisición. Esta garantía no cubre fusibles, baterías descartables o daños que sean consecuencia de accidentes, negligencia, uso indebido, alteración, contaminación o condiciones anormales de uso o manipulación.
Página 68
CAT IV 600V CAT III 1000V K-TYPE W 30V VeHzE TEMP 750V B 750V B 1000V F 1000V F ACD-3300 IND ACDC-3400 IND ➊ Mordazas para las pruebas actuales ➋ Botón HOLD ➌ Selector de funciones ➍ Botones de funciones auxiliares ➎...
Página 69
ACD-3300 IND / ACDC-3400 IND Pinzas amperimétricas industriales de verdadero valor eficaz CAT IV Símbolos ..........................69 Información relacionada con la seguridad ................ 69 Advertencias y precauciones ..................69 Desembalaje y contenido ....................70 Introducción ........................70 Funciones Auxiliares ......................70 Botón pulsador PEAK+/- ....................
INfoRMACIóN RELACIoNADA CoN LA SEgURIDAD • Las pinzas amperimétricas digitales ACD-3300 IND y ACDC-3400 IND cumplen con EN61010-1:2001; EN61010- 2-032:2002; CAT IV 600 V, CAT III 1000 V, clase II y grado de polución 2. EMC: conforms to EN61326-1.
INTRoDUCCIóN Los multímetros de pinza de verdadero valor eficaz ACD-3300 IND y ACDC-3400 IND son de rango automático hasta 1000 A CA y 750 V CA / 1000 V CC. Sus funciones incluyen tensión alterna y continua, corriente alterna y continua (ACDC-3400 IND),...
botón MAX/MIN El botón “MAX” muestra el valor máximo de una serie de mediciones. El botón “MIN” muestra el valor mínimo de una serie de mediciones. Aparece y parpadea “MAX/MIN” en la pantalla LCD para mostrar el valor que se está midiendo. Para salir, pulse el botón MAX/MIN durante más de 2 segundos.
Medición de resistencia (vea la figura 5) 1. Sitúe el selector de funciones en Ω. Utilice el botón ‘Ω’ para seleccionar la prueba de resistencia (ACD-3300 IND solamente). 2. Conecte los conductores de prueba: El rojo al terminal +, el negro al terminal CoM.
1. Fije el selector de funciones en la posición ““. Utilice el botón ‘Ω’ para seleccionar la prueba de diodos (ACD-3300 IND solamente). 2. Conecte el conductor de prueba de color rojo a la toma “VΩ” y el conductor de prueba de color negro a la toma “COM”.
Dimensiones: ACDC-3400 IND: 281 x 108 x 53 mm (11,1 x 4,3 x 2,1 pulg.) ACD-3300 IND: 279 x 103 x 53 mm (11 x 4,1 x 2,1 pulg.) Peso: ACDC-3400 IND: 559 gm (1,23 lb.) ACD-3300 IND: 500 gm (1,10 lb.) Seguridad: LVD cumple con EN61010-1:2001 y EN61010-2-032:2002, CAT III 1000 V, CAT IV 600 V, clase II y grado de polución 2...
66,00 A*, 660,0 A, 1000 A 50 a 400 Hz ± (3,0 % lect. + 200 dígitos) * ACD-3300 IND solamente ** Frecuencia: 10 % a 100 % del rango actual TRMS acoplado con CA: 5 % a 100 % del rango Factor de cresta: ≤...
± (3,0 % lect. + 10 dígitos) 6,6 mF ± (5,0 % lect. + 10 dígitos) Protección contra sobrecargas: 1000 V CC o 750 V CA rms TEMPERATURA (ACD-3300 IND solamente) Rango Exactitud 0,0 °C a 400,0 °C ± (1,0 % + 1 °C) -35,0 °C a 0,0 °C, 400 °C a 1000 °C...
Tensiones de circuito abierto: 3,2 V CC típico Indicación acústica: < 0,03 V Protección contra sobrecargas: 1000 V CC o 750 V CA rms CONTINUIDAD Rangos: 660,0 Ω Indicación acústica: < 30 Ω Tiempo de respuesta: 500 ms Protección contra sobrecargas: 1000 V CC o 750 V CA rms FRECUENCIA (rango automático) Rango Exactitud...
Página 79
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 2. Tensión \ Frecuencia \ Ciclo de trabajo HOLD 1000A 660A 1000 A 600 A Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V...
Página 80
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE µ F CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 4. Capacitancia HOLD 1000A 660A Δ ZERO PEAK ± MAX/MIN RANGE kΩ CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F...
Página 81
1832 ºC 1000 ºF ºF PEAK ± MAX/MIN RANGE Cal > 2 sec RANGE °F CAT IV 600V CAT III 1000V K-TYPE W 30V TEMP 750V B 1000V F Fig 6. Temperatura (ACD-3300 IND solamente) Fig 7. Reemplazo de baterías...
Página 83
Fax: 905-890-6866 Reparationer och utbyten utan garanti – Europa ® Enheter i Europa, som ej täcks av garanti, kan bytas ut av din Amprobe Test Tools- distributör för en nominell kostnad. Avsnittet “Where to Buy” på www.amprobe.com innehåller en lista över distributörer i närheten av dig.
Página 84
CAT III 1000V CAT IV 600V CAT III 1000V K-TYPE W 30V VeHzE TEMP 750V B 750V B 1000V F 1000V F ACD-3300 IND ACDC-3400 IND ➊ Klämmor för Strömtest ➋ HOLD-knapp ➌ Vred för funktionsval ➍ Knappar för hjälpfunktion ➎...
Página 85
ACD-3300 IND/ACDC-3400 IND CAT IV Industriell True RMS klämmätare Symboler ..........................85 Säkerhetsinformation ......................85 Varningar och Försiktighetsåtgärder ..............85 Uppackning och InnehÅll ....................86 Introduktion ........................86 Hjälpfunktioner ........................86 PEAK +/--knapp ......................86 Den används för att registrera de högsta (+) och lägsta (-) mätvärdena för AC- spänning och AC-ström.
strömförande ledare är tillåtet SäkERHETSINfoRMATIoN • ACD-3300 IND och ACDC-3400 IND Digital Clamp meters uppfyller EN61010-1:2001; EN61010- 2-032:2002; CAT IV 600 V, CAT III 1000 V, klass II och föroreningsgradering 2. EMC: conforms to EN61326-1. • Alla instrument är EN61010-1-certifierat för installationskategori IV (600 V). Det rekommenderas för användning i installationer på...
Om någon artikel är skadad eller saknas ska hela paketet omedelbart returneras till inköpsstället för utbyte. INTRoDUkTIoN ACD-3300 IND och ACDC-3400 IND True RMS klämströmsensorer har automatiskt områdesval upp till 1000 ACA och 750 Vac / 1000 Vdc. Dess funktioner inkluderar AC / DC-spänning (ACDC-3400 IND), frekvens, driftscykel, diod, motstånd, kapacitans, kontinuitetstest samt relativ (ACDC-3400 IND).
ZERo (Relativa)-mätningar (endast ACDC-3400) Läget Relativa visar skillnaden mellan den verkliga avläsningen och ett referensvärde. Det kan användas med alla funktioner och områden. För att utföra en relativ mätning ska först ett referensvärde etableras genom att mäta ett värde och sedan trycka på -knappen när avläsningen stabiliserats.
är kretsen en öppen krets. kontinuitetstest (se fig. 5) 1. Ställ funktionsomkopplaren till position . Använd knappen ‘Ω’ för att välja -testet (endast ACD-3300 IND). 2. Anslut mätsladdarna: Röd till +, Svart till CoM. 3. Koppla bort effekten till kretsen som ska mätas 4.
3. Koppla bort effekten till kretsen under test. Extern spänning över komponenterna orsakar ogiltiga avläsningar. 4. Rör vid dioden med sonderna. Ett framspänningsfall är ungefär 0,6 V (typiskt för en silikondiod). 5. Reversera sonderna. Om dioden är OK kommer ”OL” att visas. Om dioden är kortsluten kommer ”0.00”...
Livslängd batteri: typiskt 75 timmar med zink-kolcell; 150 timmar med alkaliskt Dimensioner: ACDC-3400 IND: 281 x 108 x 53 mm (11,1 x 4,3 x 2,1 tum) ACD-3300 IND: 279 x 103 x 53 mm (11 x 4,1 x 2,1 tum) Vikt: ACDC-3400 IND: 559 g (1,23 lb.) ACD-3300 IND: 500 g (1,10 lb.)
Página 92
66,00 A*, 660,0 A,1000 A 50 till 400 Hz ± (3,0 % avl + 200 siffror) * endast ACD-3300 IND ** Frekvens: 10 % till 100 % av strömområde AC kopplad TRMS: 5 % till 100 % av område Crestfaktor: ≤ 3 Överbelastningsskydd: 1000 A AC...
Página 93
± (3,0 % avl + 10 siffror) 6,6 mF ± (5,0 % avl + 10 siffror) Överbelastningsskydd: 1000 VDC eller 750 VAC rms TEMPERATUR (endast ACD-3300 IND) område Noggrannhet 0,0 °C till 400,0 °C ± (1,0 % + 1 °C) -35,0 °C till 0,0 °C, 400 °C till 1000 °C...
Página 95
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 2. Spänning \ Frekvens \ Driftscykel HOLD 1000A 660A 1000 A 600 A Δ ZERO PEAK ± MAX/MIN RANGE CAT IV 600V CAT III 1000V...
Página 96
HOLD 1000A 660A 1000 Δ ZERO PEAK ± MAX/MIN RANGE µ F CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F Fig 4. Kapacitans HOLD 1000A 660A Δ ZERO PEAK ± MAX/MIN RANGE kΩ CAT IV 600V CAT III 1000V VeHzE 750V B 1000V F...
Página 97
1000 1832 ºC 1000 ºF ºF PEAK ± MAX/MIN RANGE Cal > 2 sec RANGE °F CAT IV 600V CAT III 1000V K-TYPE W 30V TEMP 750V B 1000V F Fig 6. Temperatur (endast ACD-3300 IND) Fig 7. Ersätta batteri...
Página 98
Visit www.Amprobe.com for • Catalog • Application notes • Product specifications • User manuals Please Recycle...