Step 6
Connect to gas canister
Regulators will vary depending on region.
WARNING
• Please always keep the gas bottle in upright position.
• The size for 20 lbs LP gas cylinder is 12.2 inches in diameter and 17.9 inches tall
• If the appliance is not in use, the gas must be turned off at the supply cylinder.
• The cylinder used must include a collar to protect the cylinder valve.
• The minimum distance for the appliance and the 20lb gas tank is 40 inches apart.
Connecting the liquid propane gas cylinder
1. The cylinder valve should be in OFF position.
2. Make sure the burner valve is in OFF position.
3. Inspect the valve connections, port and regulator assembly. Remove debris and inspect the hose for damage.
4. When connecting the regulator assembly to the valve, use your hand to tighten the nut clockwise until it stops.
Use of a wrench could damage the quick coupling nut and result in a hazardous situation.
5. Open the cylinder valve fully by turning the valve counter-clockwise.
6. Before lighting the oven, use a soap and water solution to check all connections for leaks.
7. If a leak is found, turn the cylinder valve OFF, and do not use the oven until local liquid propane dealer can
make repairs.
Disconnecting the liquid propane gas cylinder
1. Turn the oven burner valve OFF and make sure the oven is cool.
2. Turn the liquid propane cylinder valve OFF by turning clockwise until it stops.
3. Detach the regulator assembly from the cylinder valve by turning the quick coupling nut counter-clockwise.
4. Place dust cap for cylinder valve outlet whenever the cylinder is not in use.
8
QCC1 gas regulator
This gas fitting is clockwise. Make sure that the tank is completely switched off and screw the
regulator as far as possible into the gas tank valve.