All manuals and user guides at all-guides.com
Motor
This motor has a manual thermal
overload protector. If the motor
overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed
to cool down before restarting. To
restart:
1.
Place the On/Auto/Off lever in
the Off postion.
2.
Allow the motor to cool.
3.
Depress the red reset button on
the motor.
4.
Place the On/Auto/Off lever in
the On/Auto postion to restart
the motor.
To Replace Belt
Risk from Moving
Parts. Serious injury
or damage may occur if parts of
the body or loose items get caught
in moving parts. Never operate the
unit with the belt guard removed.
The belt guard should be removed
only when the compressor is
unplugged.
1.
Disconnect electrical supply to
the air compressor
2.
Remove the front of the belt
guard by disengaging the snaps.
Insert a flat bladed screwdriver at
each snap location and pry the
beltguard apart.
3.
Loosen the wing nut on hold
down plate and tilt motor
to allow for easy removal or
installation of the belt.
Wing Nut
4.
Remove belt.
Replace belt. NOTE: The belt
5.
must be centered over the
grooves on the flywheel and
motor pulley.
6.
Turn the wing nut on the hold
down plate until it makes contact
with the washer, plus one
additional turn.
7.
Replace the belt guard.
21- ENG
A13576