1. INSTALACIÓN
SUPERIOR SLAVE
Módulo de regulación Slave SUPERIOR
RGJ3-VCES2-SU-
INPUT
Entrée
0-10
0-10
24VAC
24VAC
VDC
VDC
1
2
1
2
24V
24V
GND
GND
24V
23 24
23 24
25 26
25 26
1
1
2
2
24VAC
24VAC
24VAC
0-10V
24VAC
0-10V
POWER SUPPLY
MIX. POINT / OUTDOOR
MIX. POINT / OUTDOOR
POWER SUPPLY
POWER SUPPLY
Vanne/ Groupe Exterieur DX
Alimentation
Alimentation
Vanne/ Groupe Exterieur DX
Alimentation
UNIT DX
UNIT DX
MIX POINT
MIX POINT
MIX POINT
vanne
vanne
MAIN ELECTRIC SUPPLY
alimentation générale
HEATER/
VENT-EXT
VENT-INT
HEATER/
VENT-EXT
VENT-EXT
24VAC
PREHEATER
24VAC
24VAC
PREHEATER
24VAC
RPM
GND GND
RPM
RPM
RPM
COOL/PUMP
1
COOL/PUMP
1
PWM
GND
GND
GND
GND
PWM
PWM
GND
GND
1
GND
PWM
GND
GND
1
~
~
~
~
2
~
~
~
(TC)
(TC)
2
0-10V GND
0-10V GND
(TC)
(TC)
0-10V
GND
0-10V
GND
13 14
15
16 17 18 19 20 21 22 23 24
25 26 27 28 29
25 26 27 28 29
30
12
11
10
9
8
FUSE
FUSE
FUSE
7
(VENT-EXT)
(VENT-INT)
6
5
4
FUSE
FUSE
FUSE
(PCB)
(PERIPHERY)
3
2
83
82
81 80 79 78 77 76 75 74 73
72 71
72 71
70 69
70 69
1
L
L
LO
LO
L
L
LO
LO
N
N
N
L
LO
L
LO
L
LO
ALARM
RUN
COOL/HEAT
ALARM
RUN
COOL/HEAT
N
230VAC
230VAC
230VAC
230VAC
230VAC
230VAC
230VAC
230VAC
HEATER
HEATER
OUTPUT
OUTPUT
HEAT PUMP
HEAT PUMP
FLAP-EXT
W. PUMP
PIR
FLAP-INT
FLAP-EXT
W. PUMP
FLAP-EXT
W. PUMP
230VAC
230VAC
230VAC
WATER
WATER
WATER
POMPE
POMPE
POMPE
PUMP CONTROL
PUMP CONTROL
DE CIRCULATION
PUMP CONTROL
DE CIRCULATION
DE CIRCULATION
OUTPUT
OUTPUT
79 80
72 71
77 78
76 75
76 75
72 71
76 75
6
6
6
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
7
7
4
5
OUTLET
(Sortie pour unité
(Output for outdoor unit)
(Sortie pour unité
(Output for outdoor unit)
(Output for outdoor unit)
Registre
exterieure)
exterieure)
Air Rejeté
70 69
68 67
70 69
70 69
68 67
4
!
!
DX GENERAL ERROR
DX GENERAL ERROR
8
8
9
9
(settable)
(settable)
E
-SL
RGJ3-VCES2-SU-
2
1
0-10
24VAC
GND
VDC
GND
GND
24
23
22
1
2
GND
23 24
25 26
49 50
49 50
1
EXT. SENSOR
EXT. SENSOR
3
2
3
24VAC
Capteur Externe.
Capteur Externe.
24VAC
0-10V
(two-wire shielded cable)
MIX. POINT / OUTDOOR
(two-wire shielded cable)
Câble deux fils blindé
Câble deux fils blindé
Vanne/ Groupe Exterieur DX
UNIT DX
vanne
HEATER/
24VAC
PREHEATER
24VAC
REC/BYP
POSTHEATER
POSTHEATER
REC/BYP
POSTHEATER
REC/BYP
COOL/PUMP
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
1
1
PWM
GND
+SSR -SSR
+SSR -SSR
~
2
0-10V
0-10V
~
GND
GND
+SSR -SSR
~
2
~
~
2
0-10V
GND
2
0-10V GND
0-10V
GND
30
31
31
32
32
33
33
25 26 27 28 29
34
34
35 36 37 38 39 40 41 42 43
35 36 37 38 39 40 41 42 43
30
31
32
33
DATA
DATA
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
72 71
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
N
PRESENCE
ALARM
RUN
COOL/HEAT
DEFROST EXTERNAL
REC ERR
DEFROST EXTERNAL
ERROR
DEFROST EXTERNAL
REC ERR
ERROR
ERROR
FIRE
BOOST
FIRE
BOOST
HEATER
HEAT PUMP
OUTPUT
ON/OFF
HEAT PUMP
HEAT PUMP
HEAT PUMP
ON/OFF
CONTACT
CONTACT
EXTERNAL
CONTACT
EXTERNAL
EXTERNAL
CONTACT
CONTACT
FIRE
FIRE
CONTROL
CONTROL
EXTERNE
CONTROL
EXTERNE
EXTERNE
OUTPUT
INCENDIE
INCENDIE
BOOST
ON/OFF
ON/OFF
BOOST
ON/OFF
72 71
3
4
5 6
7
63 64
62 61
63 64
63 64
62 61
57 58
57 58
4
5
6
DX = ON/OFF
DX = ON/OFF
7
11
12
13
11
13
11
12
(Sortie pour unité
Commande
Commande
Commande
CMSI
CMSI
exterieure)
á distance
á distance
á distance
66 65
68 67
66 65
66 65
2VV. Creating innovative solutions for you and your business since 1995.
defrost
!
defrost
DX DEFROST
DX GENERAL ERROR
DX DEFROST
DX DEFROST
10
10
8
10
9
(settable)
(settable)
(settable)
(settable)
S
-SL
RGJ3-VCES2-SU-
3
GTC
ou
ou
or
or
Control panel
Control panel
Control panel
boitier de commande
boitier de commande
boitier de commande
ModBUS RTU via
ModBUS RTU via
Rs485
Rs485
20
19
49 50
EXT. SENSOR
3
Capteur Externe.
(two-wire shielded cable)
Câble deux fils blindé
J1/J2
J1/J2
T-WATER T-WATER T-ROOM
T-WATER T-WATER T-ROOM
T-WATER T-WATER T-ROOM
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
-OUT
-IN
-OUT
-OUT
-IN
FILTER
FILTER
9
9
10
10
JP1
JP1
INT
INT
LED1
LED1
34
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
44 45 46 47 48 49 50
44 45 46 47 48 49 50
SWO
SWO
SWO
DATA
1
1
1
2
2
PRESENCE
2
PRESENCE
IN GND
IN GND
REC ERR
FIRE
BOOST
15VAC
15VAC
SENSOR
15VAC
SENSOR
SENSOR
ON/OFF
CO2/RH/EXT
CO2/RH/EXT
CO2/RH/EXT
PIR
PIR
PIR
CONTACT
FIRE
CONTACT
CONTACT
ERROR
CONTACT
ERROR
ERROR
INCENDIE
CONTACT
CONTACT
ERREUR
ERREUR
CONTACT
ERREUR
BOOST
8
9
10
11
62 61
59 60
59 60
57 58
BOOST
BOOST
BOOST
7
!
!
14
12
14
13
CMSI
CO
/ RH/VOC
CAPTEUR 0-10V
SENSOR
CO
/ RH/VOC
CAPTEUR 0-10V
SENSOR
2
2
16
16
15
15
EXTERNAL
EXTERNAL
defrost
51 52
51 52
53 54
53 54
V
-SL
in control module
24V
GND
0-10V
24V
GND
HEAT
0-10V
8
GTC
GTC
ou
or
ModBUS RTU via
Rs485
1
Sensor LPHW (incluido)
2
Conexión para la unidad SLAVE
3
Protección contra heladas (NC)
4
Control externo - (entrada, ON / OFF)
J1/J2
5
Termostato (entrada, NO / NC)
6
Contacto de PUERTA (entrada, NO / NC)
-IN
7
Señal de control de la unidad MASTER
FILTER
9
10
8
24 V CC, 0-10 V CC para válvula de agua
JP1
INT
LED1
IN GND
59 60
!
14
CO
/ RH/VOC
CAPTEUR 0-10V
SENSOR
2
16
15
EXTERNAL
51 52
53 54