Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Status 32450000 Modo De Empleo/Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
• Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heat-
ers if the flow pressure is at least 0,15 MPa.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Centre distance:
Connections G 1/2:
anti-pollution function
The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
150 ±12 mm
cold right - hot left
Cause
- Shower filter seal dirty
- Non return valve hasn't moved
back
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Flow limiter in handshower isn't
removed
- Filters are dirty
- Non return valve hasn't moved
back
Assembly see page 31

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter on single lever
mixers, please see page 33. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Operation (see page 34)
Maintenance (see page 35)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional regula-
tions (at least once a year).
Dimensions (see page 36)

Flow diagram

(see page 36)
Spare parts (see page 37)
Test certificate (see page 40)
Cleaning (see enclosed brochure)
Remedy
- Clean filter seal between shower
and hose
- Exchange non return valves
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Status 32650000

Tabla de contenido