I Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
–
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
Cooling Model
COOL / DRY Operation
FAN Operation
AUTO
AUTO
36°
61°
Swing up/down
Move up/down
Automatically
Automatically
MANUAL
MANUAL
Five stages of adjustment
Five stages of adjustment
can be made between
can be made between
0° ~ 61°.
14° ~ 36°.
Heat Pump Model
COOL / DRY Operation
HEAT Operation
AUTO
AUTO
– When the discharge air
temperature is low such
as at the start of heating
operation, the air blows
36°
at horizontal level. As
the temperature rises,
the hot air blows at a
Swing up/down
downward direction.
Automatically
– To stop this operation,
press MANUAL.
MANUAL
MANUAL
Five stages of adjustment
Five stages of adjustment
can be made between
can be made between
14° ~ 36°.
0° ~ 61°.
I Setting the Horizontal Airflow Direction
• Adjust it manually
G Use this air conditioner under the following
conditions:
Cooling Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature
32
23
Minimum Temperature
16
11
Heat Pump Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature-Cooling
32
23
(Maximum Temperature-Heating)
(30)
(-)
Minimum Temperature-Cooling
16
11
(Minimum Temperature-Heating)
(16)
(-)
G Notes
•
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
•
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
G Operation Details
COOL – Cooling Operation
•
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
•
Sense indoor temperature to select the optimum
mode.
•
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
•
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
Unit in °C
•
During Soft Dry operation, the indoor fan operates at
Low fan speed.
Outdoor
DBT
WBT
HEAT – Heating Operation
(for Heat Pump Model only)
26
43
•
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
11
16
falls, the heating capacity of the unit might be
reduced.
•
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
Unit in °C
unit.
Outdoor
FAN – Air Circulation Operation
DBT
WBT
(for Cooling Model only)
43
26
•
When the room temperature reaches the set
(24)
(18)
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
16
11
2°C below the set temperature.
(-5)
(-6)
(It is useful when using a heater).
6