Electric control box
PFC-M
OPERATING INSTRUCTION
Index
1.
Type
2.
Operating conditions
3.
Constuction
3.1.
3.1.1. Variation of parameters
4.
5.
5.1.
6.
7.
8.
8.1.
8.2.
9.
10.
Outside of box cover
11.
Inside of the box
12.
Declaration of conformity
1. Type
Type
PFC-M 18-16
PFC-M 18-20
PFC-M 18-25
PFC-M 18-30
PFC-M 18-35
PFC-M 18-40
PFC-M 18-50
PFC-M 18-60
PFC-M 18-70
PFC - M 18 - xx
PFC series (Power Factor Control)
Capacitor
450 Vc
µF
16
20
25
30
35
40
50
60
70
Capacitor
Maximum current 18A
Single-phase power
2. Operating conditions
- Mains supply 220-240V 50/60 Hz
- Rated insulation voltage: 400 Vac
- Maximum thermal protection: up to 18A
- Rated short-time withstand current: 1,5 kA
- Rated conditional short-circuit current: 1 kA
- Environment: B
- Ambient temperature from -5 °C to +40 °C
- Relative humidity: from 20% to 90% without
condensation
- Protection IP 55
- Dimensions 220x210x110, weight 1,2 kg
- Standards: IEC/EN 61439-1
3. Constuction
Control unit for a single-phase submersible pump.
Functions are controlled from the PFC-M
electronic control panel, which reads the power
factor (PF) for protection against dry functions,
without installing the level probe in the well.
The PFC-M control panel enables setting:
- The motor rated power
- The PF alarm limit
- The minimum and maximum limits for power
voltage
- Programming 4 restarts for the pump when there
is no water
- The pump working times and the stops if there is
no air in the tank (patented system).
Materials
- Thermoplastic case
- Electronic card, containing:
• Auxiliary circuit fuse
• Transformer
• Starting relay
• PFC-M electronic control panel with display
and microprocessor
• Terminals for connecting the power line
• Terminals for connecting the motor
• Terminals for connecting pressure switch or
float switch
• Terminals for connecting the RA 100 remote
alarm panel or MSP clean signal panel
• Cables for capacitor connection
- Capacitor
- Cable glands