Installing Lp Gas Tank - allen+roth Dualheat GAD19104L Manual Del Propietário

Fogón de gas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installing LP Gas Tank

To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads .
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
outdoor fire pit.
Inserting LP Gas Tank
W WARNING: Make sure LP gas tank valve is closed.
1 .
Open door .
2 .
Make sure the control knobs is in the " OFF" position (Figure 3) .
3 .
Loosen LP gas tank retainer bolt by turning counter-clockwise .
4 .
Place precision-filled LP gas tank upright into hole in outdoor fire pit base so the tank valve
is facing the gas line connection .
5 .
Secure tank by turning LP gas tank retainer bolt clockwise until tight .
6 .
Close door .
Connecting LP Gas Tank
1 .
Make sure the control knob is in the " OFF" position
(Figure 3) .
2 .
Before connecting, be sure there is no debris caught in the
head of the LP gas tank, head of the regulator valve or in the
head of the burner or burner ports .
3 .
Connect regulator/hose assembly to tank by turning knob
clockwise until it stops .
4 .
Perform leak check per "Checking for Leaks" section .
Disconnecting LP Gas Tank
1 .
Make sure the control knob is in the " OFF" position
(Figure 3) .
2 .
Before disconnecting, make sure the LP gas tank valve is
"CLOSED ."
3 .
Disconnect regulator/hose assembly from LP gas tank by
turning knob counterclockwise until it is loose .
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this outdoor fire pit.
4 .
Place the protective cap cover on the LP tank and store the tank outdoors in a well
ventilated area out of direct sunlight .
®
Checking for Leaks
W WARNING: Before using this outdoor
20 lb
9 Kg
12.2 in. / 31 cm
W WARNING: The burner must be
Burner Connections
1 .
2 .
3 .
W WARNING: Failure to inspect
4 .
5 .
Tank/Gas Line Connection
1 .
2 .
3 .
4 .
5 .
Upper Burner Lighting
W DANGER: Failure to follow these
W WARNING: NEVER light the burner
W CAUTION: Keep outdoor gas appliance area clear and free from
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
Note: The upper and lower burners are independent .
Note: This outdoor fire pit is equipped with a pilot light that allows for safer startups and
shutdowns . Pilot must be lit before main burner can be started .
Lighting
1 .
2 .
3 .
Gas Fire Pit
T M
@
Model No. GAD19104L
fire pit, make sure you have read,
understand and are following
all information provided in the
"Important Safeguards" section
on page 2. Failure to follow those
instructions can cause death, serious
injury or property damage.
replaced prior to the appliance being
put into operation if it is evident
that the burner is damaged. The
replacement burner shall be that
specified by the manufacturer.
Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank .
Visually check the connection between the
burner/venturi tube and orifice .
Make sure the burner/venturi tube fits over the
orifice .
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
Please refer to diagram for proper installation
(Figures 1 and 2) .
If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1-866-439-9800 for assistance .
Make 2-3 oz . of leak detection solution by
mixing one part liquid dishwashing soap with
three parts water .
Make sure control knobs are in the " OFF"
position (Figure 3) .
Connect LP gas tank per "Installing LP Gas
Tank" section .
Turn LP gas tank valve to "OPEN ."
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 2) .
a . If any bubbles appear, turn LP gas tank valve
to "CLOSED," reconnect and re-test .
b . If you continue to see bubbles after
several attempts, turn LP gas tank valve to
"CLOSED" and disconnect LP gas tank, per
"Disconnecting LP Gas Tank" section . Contact
1-866-439-9800 for assistance .
c . If no bubbles appear after one minute, turn
LP gas tank valve to "CLOSED," wipe away
solution and proceed .
lighting instructions may result in
serious bodily injury or death, or in a
fire or an explosion causing damage
to property.
with the cover on the outdoor fire pit.
combustible materials, gasoline and other flammable vapors and
liquids.
nests. A clogged tube can lead to a fire.
Make sure all labels, packaging and protective films have been removed from the outdoor
fire pit .
Check for obstructions of airflow to the burner . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner tube can lead to a fire .
The control knobs must be in the " OFF" position (Figure 3) .
9
Figure 1
LP Gas Valve
LP Gas
Connection
with Orifice
Figure 2
X
X
X
X
X
Figure 3
OFF / APAGADO
Figure 4
Figure 5
11.8 in. – 19.7 in.
30 – 50 cm

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

2592447

Tabla de contenido