Descargar Imprimir esta página

Palazzetti ECOFIRE AURORA U.S Manual Del Usuario página 16

Publicidad

SCHEMA ELETTRICO - WIRING DIAGRAM - SCHÉMA DE CÂBLAGE
ELEKTRISCHER SCHALTPLAN - DIAGRAMA DE CABLEADO - EL-DIAGRAM
1. IGNITER
comb
2. COMBUSTION FAN
Air
3. ROOM FAN
4. PELLET AUGER
5. STB SAFETY
Pa
6. UNDER PRESSURE SAFETY
7. HALL SPEED SENSOR
8. PELLET PROBE
9. ROOM PROBE
K
10. FLUE GAS TEMP.
UI /
11. USER INTERFACE
PC
12.
INDUCTANCE
13. EXTERNAL THERMOSTAT
ITALIANO
1 Sensore di hall
2 Termostato esterno
3 Sonda ambiente
4 Sonda pellet
5 Sonda fumi
Differenziale di
6
pressione
7 Resistenza ad
incandescenza
Ventilatore scarico
8
fumi
10 Dosatore caricamento Feeding system
Termostato di
11
sicurezza
12 Pressostato
13 Sensore porte
air
14 Ventilatore ambiente Room fan
15 Induttanza
UI /
Pannello comandi
PC
16
11
UI /
PC
PE
BROWN
BLUE
PE
L
N
* Solo nei modelli ventilatore con condensatore
Vac
* Only in models with a condenser room fan.
~220÷240
ENGLISH
FRANCAIS
Exhaust fan speed
Capteur de hall
sensor
Thermostat
Thermostat
Room probe
Sonde ambiant
Pellet probe
Sonde pellet
Flue probe
Sonde des fumees
Differential de
Pressure differential
pression
Igniter
Resistance
Extracteur des
Exhaust fan
fumees
Systeme
d'alimentation
Thermostat
Thermostat
Vacuum switch
Pressostat
Door sensor
Sonde porte
Ventilateur ambiant
Inductance
Inductance
Tableau de
Display
commande
00 477 7210 08/2018 - PN - Italy
C01
GND
F03
F01/02 +VIO
~220 - 240 Vac
O01
L
N
1
DEUTSCH
Hall fuehler
Raumtemperaturregler Termostato
Raumsonde
Pelletsonde
Rauchsonde
Druckdifferenzial-sensor Diferencial de presion
Glutwiderstand
Abgasventilator
Spender
Raumtemperaturregler Termostato
Druckwaechter
Tuersonde
Raumluftgeblaese
Induktivität
Steuerpaneel
7
13
8
9
t° L
T02
T01
GND
I02
I01
O02
O03
O04
12*
2
3
4
5
comb
Air
cod. 00 472 3182 - ver. 08.2017
ESPAÑOL
Sonda regulad. Veloc.
Turbina humos
Sonda ambiente
Sonda pellet
Sonda humos
Resistencia
Turbina expulsion
humos
Dosador
Presostato
Sensor puerta
Ventilador de
conveccion
Inductancia
Panel de mando
10
K
T03
+
-
6
Pa
DANSK
HALLSENSOR
EXTERNE
THERMOSTAAT
KAMERSENSOR
SONDE PELLET
ROOKGASSENSOR
DIFFERENTIEELRELAIS
DRUK
GLOEIWEERSTAND
ROOKGASSEN
VENTILATOR
DOSEERINRICHTING
LADING
VEILIGHEIDSTHERMOSTAAT
DRUKREGELAAR
SENSOR DEUREN
OMGEVINGSVENTILATOR*
indukcji
Panel sterowniczy

Publicidad