Cable Selection
12 VOLT TAP
Total Fixture Wattage
0-60 Watts
61-120 Watts
121-180 Watts
181-240 Watts
241-300 Watts
600W Transformer = (2x300 Watts)
900W Transformer = (3x300 Watts)
15 VOLT TAP
Total Fixture Wattage
0-60 Watts
61-120 Watts
121-180 Watts
181-240 Watts
241-300 Watts
600W Transformer = (2x300 Watts)
900W Transformer = (3x300 Watts)
* NOT RECOMMENDED FOR HALOGEN LANDSCAPE LIGHTS
NOTE: Most LED landscape fixtures can operate with full illumination from 9V all the way to as little as 6V. It is possible to have extended length runs with LED
fixtures that go beyond the specifications shown on the charts above.
Troubleshooting
Problem
Possible Cause
□ There is no power.
The lights do not turn on.
□ There is a disconnection or break in the wire.
□ The transformer setting is incorrect.
□ There is a loose wire connector to the fixture.
The lights flicker.
□ There is a loose connection at the transformer.
The lights flicker (all
fixtures).
Care & Cleaning
□ Before attempting to clean the fixture, disconnect the power to the fixture by turning the breaker off or removing the fuse from the fuse box.
□ To clean the fixture, use a dry or slightly dampened clean cloth.
□ Do not use cleaners with chemicals, solvents, or harsh abrasives, as damage to the fixture may occur.
Warranty
WHAT IS COVERED
The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period of five (5) years from date of purchase. This
warranty applies only to the original consumer and only to products used in normal use and service. If this product is found to be defective, the manufacturer's only
obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturer's discretion, provided that the product has not been damaged
through misuse, abuse, accident, modifications, alterations, neglect, or mishandling.
WHAT IS NOT COVERED
This warranty shall not apply to any product that is found to have been improperly installed, set-up, or used in any way not in accordance with the instructions
supplied with the product. This warranty shall not apply to a failure of the product as a result of an accident, misuse, abuse, negligence, alteration or faulty
installation, or any failure not relating to faulty material or workmanship. The warranty shall not apply to the finish on any portion of the product, such as surface
and/or weathering, as this is considered normal wear and tear.
The manufacturer does not warrant and specially disclaims any warranty, whether express or implied, of fitness for a particular purpose, other than the warranty
contained herein. The manufacturer specifically disclaims any liability and shall not be liable for any consequential or incidental loss or damage, including but not
limited to any labor/expense cost involved in the replacement or repair of said product.
Contact the Customer Service team at 1-855-HD-HAMPTON or visit www.HamptonBay.com
0-50 feet
16 AWG
16 AWG
14 AWG
14 AWG
12 AWG
NOT RECOMMENDED
12 AWG
NOT RECOMMENDED
12 AWG
NOT RECOMMENDED
0-50 feet
16 AWG*
16 AWG*
14 AWG*
14 AWG*
12 AWG*
12 AWG*
12 AWG*
□ Check the outlet and ensure that a breaker or GFCI circuit has not been
tripped.
□ Follow the wires from the fixture and ensure a continuous connected path
back to the transformer.
□ Check the settings on the transformer.
□ Tighten the wire connector and ensure the metal contacts pierce the
insulation on the low voltage cable from the transformer.
□ Unplug the transformer from the outlet and visually inspect the positive and
negative connecting posts. Each wire should be securely screwed in and
not in contact with any other.
Cable Length
51-100 feet
16 AWG
14 AWG
12 AWG
12 AWG
Cable Length
51-100 feet
16 AWG
16 AWG
14 AWG
14 AWG
12 AWG
12 AWG
12 AWG
Solution
Please contact 1-855-HD-HAMPTON for further assistance.
101-150 feet
14 AWG
12 AWG
NOT RECOMMENDED
NOT RECOMMENDED
NOT RECOMMENDED
NOT RECOMMENDED
NOT RECOMMENDED
101-150 feet
16 AWG
12 AWG
12 AWG
12 AWG
NOT RECOMMENDED
NOT RECOMMENDED
NOT RECOMMENDED