Translation of the original instructions
The headband can potentially cause allergies in sensitive
individuals.
The operating temperatures of the optoelectronic filter are
from -10°C to +55°C.
The opto-electronic filter in the mask is not waterproof and
will not function properly if it has been in contact with water.
The welding mask must be moved carefully to avoid damage
to the filter, guards and/or protective shell.
Maintenance :
- Do not place heavy objects or tools on or in the facepiece
to avoid damage to the filter or face shields.
Mask storage temperatures range from -20°C to +70°C.
- Clean the Optoelectronic Filter with a clean cotton or
special lens cloth.
- Regularly clean and change the guard screens.
- Clean the inside and outside of the mask with a neutral
detergent-disinfectant. Do not use solvents.
- Make sure that the sensors and cell are not obstructed by
dust or debris.
- We recommend using the mask and visors for 5 years.
The length of use depends on various factors such as type
of use, cleaning, storage and maintenance.
BEFORE WELDING
-Check that the welding helmet is in good condition and headband adjustment.
-Check whether the front cover lens, the front frame and filter are inserted and fixed in place. In case of anomalie, please proceed to its reconditionning.
-Make sure that the 4 sensors (9) and the cell (8) are not obstructed by dust or debris.
-Make sure that the protection films on both screens are removed.
-Make sure that the red light (1) is off, otherwise change the batteries (7).
-Check that the protection level matches your welding processes. Please refer to the following chart to help your choice (cf. welding process board)
OPERATION
The opto-electronic GYSMATIC LCD 9.13 G welding helmet instantaneously switches from light to dark state when a welding arc is struck and switches back to the light state
when the arc stops.
• The Low battery indicator blinks when the battery replacement is required. (2 coin type CR 2450, 3V).
1
• Shade potentiometer : The shade number can be set manually between Din 9 to 13. Select a shade number by the internal knob.
2
SHADE
• Internal sensitivity potentiometer : Sensitivity adjustment according to :
- Light ambient: Without welding, turn the sensitivity setting towards «max», then turn the sensitivity setting towards «low» until filter lightens.
3
- Welding process: «Max» position for low amperage TIG rpocess / Medium range for most application.
GYSMATIC TRUECOLOR 9.13
1
2
3
4
5
8
10
9
6
7
7
1. Low charge leve
2. Shade control knob
3. Sensitivity control knob
4. Delay time control knob
5. Potentionmeter «Welding-Grinding»
6. LCD protection plate
7. Lithium batteries (CR2450)
8. Solar cell
9. Sensors
10. Filter
8
EN