Display In Different Dosing; Stand By (Stop); Prime Button; Level Probe Control (Optional) - VERDER VP2-HT TIMER Serie Manual De Regulatión

Ocultar thumbs Ver también para VP2-HT TIMER Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DISPLAY IN DIFFERENT DOSING

STAND BY (STOP)

3sec
Keep pushing ESC/SBY button for 3 seconds during the functioning to put the pump in stand by mode:
1) The pump stops dosing
2) Green on led blinks
3) The display shows alternativenly "Stby" and the type of dosing (flowrate is 0%)
Push again the ESC/SBY button to return the pump to the programmed functioning.

PRIME BUTTON

Push the PRIME button shortly during the functioning to put the pump in Prime status:
1) the pump doses at 25% of maximum flowrate
2) the green LED is lit fix
3) the red LED flashes
4) display shows "Prime 25%"
Push again PRIME button to return the pump to the operating state.
NOTE: keeping pressed the PRIME button the pump will dose at 80% of the maximum flowrate and the display
will show "Prime 80%".

LEVEL PROBE CONTROL (OPTIONAL)

The closing of the level input dry contact will cause:
1) the dosage stops
2) the green ON led blinks
3) the display shows alternatively "Level" and the actual dosing mode (flowrate is 0%).
When the level contact gets opened again, the pump returns to working mode compatible with the actual inputs.
Rev 1.1
Dosing: Manual with cycle deactive;
The pump is dosing with 80% Flowrate
Dosing: Manual with cycle active;
The pump is dosing with 80% Flowrate during Ton=10 second
Dosing: Quantity
The pump is dosing 300ml (programmed ones) at maximum
Flowrate
Dosing: Timer Dos;
On the left the current day and time, the pump must finish
dosing 1liter of chemical (1000ml residues) during the day
Dosing: Timer
On the left the current day and time; on the right the next
scheduled dosage of the day: P1 dosage which will start at 13.00.
Cod. 00.009.124
20

Publicidad

Tabla de contenido
loading

Tabla de contenido