Only start work after you are familiar with the electrical engineering regulations that apply
to the local area.
Only use voltage seekers that comply with the regulations when troubleshooting. From
time to time check voltage seekers to ensure that they are operationally efficient.
2.6.1 Cables
Only use cables that are marked and rated according to the specifications in "1.1Electrical
specifications". Don't use excessive length of the cables. If a very long cable is needed we
recommend that you use a cable rated for more current and connect it to a distribution cen-
tral near the machine. Never lay the cable in a loop when operating the machine, this will cause the
cable to heat up and may cause fire. See "Figure 21" for explanation.
Figure 21
Recommended way to handle excessive cable length.
2.6.2 Using a generator
The generator must be equipped with protective earth and operated in accordance with the
current EN-VDE directives (this applies to the protective earth conductor in particular) in or-
der to ensure that all safety devices are functioning and eliminate possible damage to
electrical components.
Definition of the "Safety off position"
2.7
The machine is in a safe condition where it cannot be any hazard.
How to set the machine in the Safety off position:
1. Switch off the machine
2. If a dust collector is used, switch it off
3. Wait for all drives to come to a complete stop
4. Disconnect the main power
5. Secure against unintended restart
Always disconnect the main power at the machine end to be able to prevent other per-
sons from accidentally reconnect the main power while working on the machine.
Safety regarding maintenance
2.8
Set the machine into the Safety off position before beginning any work on the machine.
84