To Replace Regulator - Craftsman 919.167260 Manual Del Propietário

Ocultar thumbs Ver también para 919.167260:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

All manuals and user guides at all-guides.com

To Replace Regulator

1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug unit.
3.
Using an adjustable wrench or
specified wrench remove the
gauges (7/16" wrench), quick
connect (13/16" wrench), and
safety valve (9/16" wrench) from
the regulator manifold.
Safety Valve
Regulator
Manifold
4.
Remove the hose by removing
the hose clamp. NOTE: The hose
clamp is not reusable. You must
purchase a new hose clamp, see
the Parts List Manual or purchase
a standard hose clamp at a local
hardware store.
Hose Clamp
5.
Remove pump mounting screws
securing pump (one on each
side).
6.
Carefully slide pump from
brackets and out of the way.
7.
Using an adjustable wrench or
5/8" wrench remove the regulator
manifold.
Gauges
Quick
8.
Apply pipe sealant to new
Connect
regulator manifold and assemble,
tighten with wrench.
9.
Reapply pipe sealant to gauges,
quick connect, and safety valve.
10. Reassemble all components in
reverse order of removal. Make
sure to orient gauges to read
correctly and use wrenches to
tighten all components.
Regulator
Manifold
17 - ENG
Pump Mounting Screw