All manuals and user guides at all-guides.com
To Replace Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug air compressor.
3.
Remove the outlet pressure
gauge and quick connect (if
equipped) from the regulator.
4.
Remove the regulator.
Regulator
5.
Apply pipe sealant tape to the
nipple.
6.
Outlet
NOTE: Arrow indicates flow of air.
Pressure
Make sure it is pointing in the direc-
Gauge
tion of air flow.
Quick
Connect
7.
8.
Nipple
19- ENG
Assemble the regulator and ori-
ent as shown.
Regulator
Regulator
Arrow
Reapply pipe sealant to outlet
pressure gauge and quick con-
nect.
Reassemble outlet pressure
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten quick connect
with wrench.
D24588