7.
Install the new check valve (turn
clockwise).
8.
Replace the outlet tube and tight-
en nuts.
9.
Replace the shroud.
TO REPLACE REGULATOR
1.
Release all air pressure from air
tank. See To Drain Tank in the
Maintenance section.
2.
Unplug compressor.
3.
Remove shrouds.
4.
Remove the outlet pressure gauge
and quick connect from the
regulator.
regulator
Before you store the air compressor,
make sure you do the following:
1.
Review the Maintenance section
on the preceding pages and per-
form scheduled maintenance as
necessary.
2.
Drain water from air tank. See To
Drain Tank under Maintenance.
air tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
Outlet
Pressure
Gauge
Quick
Connect
STORAGE
Water will
condense in the
5.
Remove the regulator.
6.
Reapply pipe sealant to outlet
pressure gauge and quick
connect.
7.
Assemble quick connect to new
regulator and tighten.
regulator
Nipple
Arrow
8.
Apply pipe sealant tape to the
nipple.
9.
Assemble the regulator.
NOTE: Arrow indicates flow of
air. Make sure it is pointing in the
direction of air flow.
10. Use the hex on quick connect
to tightening regulator. Orient as
shown.
11. Assemble outlet pressure gauge.
Orient outlet pressure gauge to
read correctly.
12. Replace shrouds.
3.
Protect the electrical cord and
air hose from damage (such as
being stepped on or run over).
Wind them loosely around the
compressor handle.
4.
Store the air compressor in a
clean and dry location.
17 - ENG
Quick
Connect