The machine will now fill the machine bottle with the preset quantity ±1:01lb (≈ 500g). When
the quantity minus 1:01lb (≈ 500g) is reached, the machine will stop and display:
Close the bottle tap and press START. The machine will stop automatically after having
recovered the residual refrigerant from the hoses. Close the high-pressure tap. Disconnect the
external bottle. Switch the machine off.

VACUUM PUMP

Perform the operations listed below on a routine basis in order to ensure good operation of the
vacuum pump:
M1) Oil top-off.
M2) Oil change.
When topping-up or replacing the pump oil, use only the oil recommended by the
manufacturer. Contact your retailer for information concerning the correct type of oil.

M.1) Oil top-off

This operation must be performed when the level of the oil falls to less than half on the indicator
(4) (refer to Figure 10). NOTE: in order to correctly check the oil level, run the pump for at least
1 minute (running a vacuum procedure in the hose for 1 minute) so that the oil fluidifies. Check
the oil level when the pump stops. To refill the oil, perform the steps listed below in the order
given. Disconnect the MACHINE from the mains supply. Locate the oil cap (2) and screw it
completely off. The oil must be added through the hole in which the oil cap was lodged (2).
Add oil a little at a time, waiting for the level to rise before each successive addition, until the oil
level is about 0.2 inch (½ cm) above the red mark on the indicator (4). Replace the oil cap (2)
and tighten down.

M.2) Oil change

The vacuum pump oil must be replaced every 150 working hours or when the refrigerant filters
are replaced. The oil must also be replaced whenever it changes color due to absorption of
humidity. Before beginning the oil change procedure, procure a container of at least 16 oz. (1
pint) capacity in which to collect the used oil. The pump contains about 16 oz. of oil. Use only
the oils recommended by the manufacturer (Flo-Dynamics part number 90808).
1) Disconnect the machine from the mains supply.
2) Unscrew the filling cap 2 (refer to Fig. 10).
3) Unscrew the drain cap 3.
4) Allow all the oil to run out into a disposal container (with height < 10 cm).
5) Close the drain cap 3.
6) Pour in new oil through the filling hole, opened previously, until the level rises to the
midpoint on the indicator 4.
7) Replace the oil cap 2 and tighten.

REPLACING THE DRYER FILTERS

Replace the filters whenever the machine gives the service alarm during the first ten seconds
of operation or whenever the humidity gauge ("c" in Fig. 6) signals the presence of humidity in