Feed Water Supply; Optional Installation - GE PNRQ20RBL Manual Del Propietário

Ocultar thumbs Ver también para PNRQ20RBL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FEED WATER SUPPLY

Check and comply with local plumbing codes as you plan, then install a cold feed water supply fitting.
A. PREFERRED INSTALLATION
Utilizing existing kitchen sink water supply valve
and removable faucet tubing.
A typical connection using the included water supply
fitting is shown in the illustration below.
1. Close the water shut-off valve that is
immediately in front of the supply tube and
open the faucets to drain water from the sink
cold water pipe.
2. Remove the nut that connects the cold water
faucet to the supply tube. Some water may spill
out.
NOTES:
• Be sure to turn off the water supply and open
a faucet to drain the pipe.
• Make sure the gasket is installed in the water
supply fitting.
Cold
Water
Faucet
Stud
Cold
Water Pipe
Cold Water Shut-Off
3. Hand-tighten the water supply fitting onto the cold
water faucet. Be sure the gasket, as shown, is in
place before final assembly. Finish tightening with
an adjustable wrench. Be careful not to over
tighten or cross-thread, since damage to the
threads can occur. Make sure the 1/4" quick
connection is not against a wall that causes the
supply tubing connection to bend. A quarter turn to
tighten or loosen the adapter may be necessary to
avoid this.
4. Reconnect faucet tubing line to the fitting.
5. Install tubing. (See Installing the tubing section.)
Installation Instructions
Gasket
Water Supply Fitting
"
1/4
Tubing to
Water Filter Inlet
Fig. 1
B. OPTIONAL INSTALLATION 1
Utilizing existing kitchen sink water supply valve (A)
and removable faucet tubing (B).
1. Refer to illustration below to complete
assembly depending on supply valve
size (A).
2. Close the cold water supply valve (A) under the
sink.
3. Unscrew the flexible tubing line (B) from the
supply valve (A) that connects to the COLD
water riser.
NOTE: For rigid pipe, see D. Optional Rigid Pipe
Installation on page 11.
Note Adapter (C) orientation:
3/8" installation—Rounded end of adapter (C)
connects to supply valve (A).
1/2" installation—Rounded end of adapter (C)
connects to coupling (D), then to existing faucet
tubing (B).
For 3/8" Plumbing
(B) Faucet
tubing line (not
included)
(D)
Coupling
(C)
Adapter
(G)
Gasket
(A) Cold water
supply valve
(not included)
10
For 1/2" Plumbing
(B) Faucet
tubing line (not
(H) Ferrule
included)
(F) Inlet valve
(I) Nut
(F) Inlet valve
(G) Gasket
(A) Cold water
supply valve
(not included)
(D)
Coupling
(G) Gasket
(C) Adapter

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pnrq21rbnPnrq21rrb

Tabla de contenido