Cerwin-Vega CVX Serie Guia De Inicio Rapido página 5

Altavoces alimentados
Ocultar thumbs Ver también para CVX Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

(F)  
THRU 1 & THRU 2 OUTPUT JACKS 
The balanced XLR outputs THRU 1 & THRU 2 are parallel connections to the respective INPUT 1 and 
INPUT 2. The level controls for INPUT 1 & INPUT 2  will not affect the signal on the direct output 
connection.  
(G)  
MIX OUTPUT 
This connection is designed to provide an output which combines all three input channels together 
for connecting to another CVX powered speaker or a recording device.  This output is not affected 
by changes to the MAIN LEVEL knob but is affected by the levels set on each channel GAIN knob.  
 
(H) MAIN LEVEL KNOB & REMOTE VOLUME CONTROL 
It is highly recommended to have the MAIN LEVEL set to the minimum (MIN) level upon initial system 
start‐up and it can be adjusted two different ways. On the MAIN LEVEL knob, volume is increased in 
a clockwise rotation and decreased in a counter‐clockwise rotation. Another method to control the 
volume is by using the REMOTE connection. A removable three‐terminal jack can be wired over long 
distances to a remote volume control device with a corresponding connection. 
 
(I )
INDI CATORS 
Three indicators provide operating condition status: 
1)
The POWER indicator (green) will illuminate when power is properly applied to the CVX 
speaker and the main power switch is ON.  
2)
The CLIP indicator (yellow) will illuminate when the CVX speaker automatically reduces 
the sound output to prevent damage to the speaker. While the CVX speaker is producing 
sound, it is suggested to reduce the volume level so the CLIP indicator does not illuminate. 
Continuing  use  of  the  CVX  speaker  while  this  indicator  is  illuminated  may  result  in  a 
PROTECT condition where no sound can be produced. Note, upon initial power up the 
indicator will blink. This is normal behavior.  
3)
The PROTECT indicator (red) will illuminate when the CVX speaker automatically places 
itself into a condition where sound output is shutoff. This condition may be the result of 
excessive  limiting,  an  excessive  heat  condition,  or  a  low  voltage  condition.  These 
conditions all can cause significant damage to the product. 
(J)
CUSTOM FEATURES 
  
MAI N/MONITOR MODE 
The CVX‐10/CVX‐15 powered speaker has a switch for selecting which operational mode the speaker 
is in: MAIN or MONITOR. MAIN should be used when the speaker is mounted vertically on a speaker 
pole. MONITOR should be used when the speaker is placed horizontally on the ground. 
 
MAIN EQ 
When the speaker is in MAIN mode, there are two available settings: LIVE and PLAYBACK. LIVE is 
suited for live sound applications while PLAYBACK is better for playback of recorded music like with 
a mobile DJ. 
 
HIGH PASS 
When turned ON, the HIGH PASS switch attenuates overall frequency output below the indicated 
frequency.  This  is  recommended  where  low  frequencies  need  to  be  attenuated  such  as  in 
combination with a subwoofer or to reduce stage rumble when the speaker is used as a floor monitor 
or in situations  
FRONT CLI P INDICATOR 
Setting the FRONT CLIP INDICATOR switch to 'ON' will enable the clip indicator light on the front of 
the CVX subwoofer for situations where it needs to be visible like during a sound check. 
 