TROUBLESHOOTING
F A U L T
Water drips out
Unit was unplugged before
when moving unit
purging was complete.
Unit does not
Unit not switched on.
operate
No power to machine.
Blower wheel not
Obstructed blower.
turning
Not enough time to dry.
Unit operating,
Poor air movement in room.
but room not dry
Excessive moist air infiltration.
Room air is dry.
Room temperature is too low.
Unit collects too
HAF filter is full.
little water
Heat exchange block and/or
coils are clogged.
If the problem you are experiencing is not listed here, contact your Aramsco location for further assistance.
SPECIFICATIONS
Model
Weight
Dimensions
(H × D × W)
Power
Water removal AHAM
(80°F/60% RH)
Water removal max.
Water removal low grain
(80°F/20% RH)
Process air (max.)
Noise level (avg.)
Air filter
Drain hose
Power cord
Construction
Safety
Specifications are subject to change without notice. Some values
may be approximate.
*Fan speed varies automatically for optimized performance.
07-01922C F532-120V 2015-03 Warranty 07-01939
C A U S E
Syclone LGR Model LGR145
#53480 Syclone
115 lbs. | 50 kg
33.5 × 20 × 20 in. | 85 × 51 × 51 cm
9.8 amps, 115V
145 pts. | 68.6 L / day
235 pts. | 111 L / day
17 pts. | 8 L / day
280 CFM* | 476 CMH*
65 dB
3M™ HAF filter
Part no. 55315 (24 pack)
40 ft. | 12.2 m
25 ft. | 7.6 m
Rotomolded shell
Certified to CSA Std C22.2 No. 92
S O L U T I O N
Purge unit before moving. See "At the End of the Job," p. 4.
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Remove duct ring and grill and remove obstruction. Replace
duct ring and grill.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Clean or replace as necessary.
Check heat exchange block and coils. Clean as necessary.
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.
20