environment, contact your Aramsco location for
assistance.
Set up drain hose
The Syclone LGR condensate pump connects to a
plastic drainage hose that is located in the pocket on the
side of the unit. This hose is equipped with a quick-
connect fitting for quick attachment to the provided 40 ft.
(12 m) drain hose. Unwrap the entire hose and place the
unattached end in a sink, drain, bucket or outdoors –
anywhere that water can drain out safely. If you use a
bucket or other container for water collection, check it
regularly to prevent overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled on the unit and do
not place the end of the hose higher than 20 ft. (6 m)
above the bottom of the unit. Also check for kinks or
other obstructions that might restrict the flow of water.
Obstructions may cause a water backup and result in
overflows.
Plug in electrical cord
The Syclone LGR dehumidifier should be plugged
into a GFCI-protected 115 volt outlet rated for at least
15 amps. Remove the cord from its storage pocket and
uncoil it. Always plug the cord firmly into the unit first,
and then plug the other end into a suitable outlet.
Turn the unit on
The control panel on the Syclone LGR dehumidifier has
a display and a touchpad with four keys. Press the
ON/OFF to turn the unit on.
CONTROL PANEL
ON/OFF
ON/OFF
Press and release to turn unit on
or off.
DISPLAY MENU
Press to select next item in menu. Menu
item will show in display.
MENU SELECTION /
Press to toggle or select values in menu
UP KEY
displayed.
PURGE PUMP
Press and release to start purge. Display
will count down seconds remaining until
purge is complete.
07-01922C F532-120V 2015-03 Warranty 07-01939
PURGE
MENU
MENU
SELECTION /
UP KEY
Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit's self-diagnosis
procedure and no user intervention is required.
Once the self-diagnosis is complete, the display will
switch to normal display mode.
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see "Job Hours Reset"
below). The second line of the display alternates
between inlet temperature and inlet humidity.
User Settings Menu
A number of settings may be changed by the user.
System information can also be displayed. These items
are accessed by pressing
press of the key will display the next parameter. When
you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press
DISPLAY MENU again to accept the setting and re-start
the display cycle. If no keys are selected for 20 seconds
the display will automatically reset and return to the
normal display mode.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
All settings and modes are discussed in detail in Control
Panel Guide, p. 3.
Error messages
If the Syclone LGR onboard diagnostics discover a
problem, the unit will display an error message. See
"Error Messages," p. 8, for an explanation of each
message.

Control Panel Guide

ON/OFF. Press to turn the unit on or off. When the
machine is turned on, the display normally reads
PLEASE WAIT COMP. DELAY and performs a numeral
countdown from a maximum of 60 seconds to 0. This
delay allows time for refrigerant pressures to equalize for
easier starting. Once the unit completes the compressor
delay, the display shows UNIT ON XX HRS and cycles
between INLET XX°F and INLET XX%. NOTE: If no
compressor delay countdown is displayed, a delay is not
necessary and the machine will begin operation
immediately.
DISPLAY MENU. Press to cycle through the display
of additional dehumidifier conditions and User Settings.
To return to the main menu, press the ON/OFF key
once.
MENU SELECTION. Press to change the values of
the "User Defined" settings. The MENU SELECTION key
acts as the UP key for adjusting the setpoint for
Humidistat mode operation. See User Settings Menu
(below) for details.