PUMP 1 RED LED
PUMP 2 RED LED
ALARM RED LED

15. MAINTENANCE, REPAIR AND WARRANTY

It is recommended to check the device periodically and regulate its operation to the actual
situation of the installation.
Failure to follow the instructions provided in this instruction manual and / or any intervention on
the device that is not carried out by authorized services and / or the use of non-original spare
parts will void the warranty, and will exempt the manufacturer from any liability in the event of
accidents to people or damage to property and / or the product itself.
Once the product has been received, verify that it has not suffered significant damages or dents.
If so, advise the person who made the delivery. After removing the device from its packaging,
check that it has not been damaged during transport. If this happened, inform the dealer.
Verify on the device label that the features shown are what you ordered. In case a fault is not
within those provided in the "ALARMS" table, contact the nearest authorized dealer.

16. ENVIRONMENTAL DISPOSAL AND TREATMENT

To carry out the elimination of the parts that make up the device, it will be necessary to adhere
to the regulations and laws in force of the country where the product is being used. In any case,
please do not throw polluting parts into the environment.
This symbol on the product indicates that it cannot be disposed of with household
waste.
This provision only refers to the disposal of equipment in the territory of the European Union
(2012/19/EU). It is the responsibility of the user to dispose of the device by returning it to
a designated collection point for recycling and disposal of electrical equipment. For more
information about equipment collection points, contact your local waste disposal agency.
28
Indicates that pump
1 is blocked from
the software or that
pump 1 is stopped
due to working with
excessive consumption
or, if enabled, due to
working without water.
Same as pump 1 red
led but for pump 2.
Indicates that the
destination tank is fill
of water.
If disabled by software, access the
Operating Modes menu and enable
the pump.
If it is stopped due to over
consumption, check the nominal
consumption entered.
If stopped for dry running check for
water in pump suction and adjust the
detection sensitivity.
Same as pump 1 red led but for
pump 2.
The red led is also activated when
STOP/AUTO is pressed.
Check that the tank is not about to
overflow with water.
Press the STOP / AUTO button again
to enable the pumps to run.