3.3 Function
Pump tubes for series B1/B2 are designed to deliver pure, turbid, aggressive or non aggressive liquids.
Check the compatibility of the pump tube for the medium in question with the aid of a resistance table
and the table of materials (→ Annex, table 6).
4. Transport and storage
4.1 Transport
Unpacking and checking condition of delivery
► Unpack the pump tube on receipt and check for transport damages.
► Report transport damages to the manufacturer immediately.
► Check that the consignment is complete as ordered.
4.2 Storage
!
WARNING
Danger of injury and intoxication when handling hazardous liquids!
► Always wear protective equipment when working on the pump.
► Complete emptying of pump tube.
► Store the pump at a protected and easy accessible place.
► Pump tubes made of polypropylene (PP): Protect against UV light.
5. Installation/Assembly and connection
5.1 Assembly of pump tube and motor
(→ Operating instructions motor).
5.2 Fixing of the pump tube
!
CAUTION
Danger of injury due to tipping over of empty drums and containers!
► The pump tube must always be positioned vertically in the bunghole.
► If necessary, use a drum adapter or emission control drum adapter.