3.6.7. Calibration of the water temperature measurement
→ If the temperature sensor is disabled, the menu below does not appear.
Menu
From - to + 5°C compared to the measurement displayed,
Parameters
Temp. Adjust
3.6.8. Calibration of the salt rate measurement
→ If the salt sensor is disabled, the menu below does not appear.
Menu
Parameters
Salt Adjust
3.6.9. Calibration of the pH measurement
Menu
pH Regulation
Adjust
3.6.10. Setting the inversion frequency of the current supplying the cell
I
Current inversion aims to prevent scale deposits on the cell. Current inversion must be set following the table
below in order to ensure that the cell continues to operate correctly in the long term.
Water hardness (°f)
Inversion frequency (h)
Menu
Electrolysis
Inversion
XX h
3.6.11. Selecting the chlorinator operating mode
Menu
(depending on model)
Electrolysis
Mode
XXX
→ The choice of operating mode can be seen on the initial display («
Possible settings
in increments of 0.5.
Possible settings
From 1.5 to 8 g/L, in increments of 0.5.
Possible settings
From 6.5 to 7.5, in increments of 0.1.
0 to 5
16
Possible settings
From 2 to 24 h, in increments of 1.
Possible settings
Continual production, following the
%
production setpoint.
Inspection of production using the
ORP probe, according to the ORP
ORP
setpoint and the ORP production
setpoint.
OFF
Deactivation of the chlorinator cell.
5 to 12
12 to 20
10
8
Meaning
PROD
Default setting
Measurement displayed
Default setting
Measurement displayed
Default setting
Measurement displayed
20 to 40
40 to 60
6
4
Default setting
Default setting
• For UNO and DUO models : %.
• For PRO model : ORP.
» as a %, or «
» in mV).
ORP
> 60
2
6 h
9