Safety; Wintering Mode; Alarms - Majestic UNO Instrucciones De Uso

Electrolizador de sal
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.7. Safety

3.7.1. Wintering mode

• Wintering mode :
- is activated by default.
- starts automatically as soon as the water temperature drops below 15°C.
• When wintering mode is on :
- The message «
Low Temp Mode
- Production is stopped.
- The pH regulation is maintained if it is activated.
• To switch off wintering mode : press on OK.
• To disable wintering mode : go to the «

3.7.2. Alarms

• All alarms are activated by default.
• Any alarm that is activated immediately appears on the screen.
• To dismiss an alarm : press the OK or
IMMEDIATE
MESSAGE
AUTOMATIC ACTION
DISPLAYED
/ FAULT
Stopping
DETECTED
production
Alarm
No
pH Can empty
Alarm
Yes
Cell Current
» is displayed.
Parameters - Alarms
button (short or long press, depending on the alarm).
Stopping
CAUSE
pH
regulation
pH corrector container
Yes
empty.
No
Cell problem.
», «
» menu.
Alarms - Low Temp
CHECKS AND REMEDIES
Replace
the
pH
container.
• Check that the cell is not scaled.
• Inspect and adjust if necessary
the inversion frequency of the
current
supplying
Electrolysis
-
menu).
• Check
that
the
connections to the terminals of
the cell are sufficiently tight and
not oxidised.
• Check that the cell's power
cable is in good condition.
• Check that the cell's power
cable connector is correctly
connected to the electronics
unit.
• As a last resort, replace the cell.
OPTION TO
DEACTIVATE
VIA THE
MENU
«
Parameters -
»
Alarms
corrector
Yes
the
cell
»
Inversion
electrical
No
14