INITIAL SETUP

1 - Plug the device into the mains.
2 -Take your mobile or tablet, connect the wifi and a network called "Toolmicroxxxxx" will
appear, the "x" are numbers, each unit is different.
3 -Click on "connect" the default password is: 12345678
Once connected, open the browser and type in the address bar toolmicro.com and press
"search" or "Go" If a message similar to:
"YOU WANT TO AUTHENTICATE IN Toolmicro" Click YES or OK.
Configure the equipment with your data, on the following sheet you have a description of what
each parameter is. That page will appear in your browser.
Once the configuration is finished, the system will reboot.
Turn off the Wi-Fi of your mobile so that it does not connect to the VM5-VigiPro.
If the data entered is correct and the Wi-Fi is active, after 5 minutes you will receive an e-mail
with this text:
Supervisor Mi-casa NORMAL CONDITION
"The text My-home, here is an example will put the name you have configured."
If you have received the e-mail, the equipment is properly configured and nothing more needs
to be done.
From that moment, if the power supply fails for more than 50 minutes, you will receive another
e-mail informing you of the failure.
If you do not receive any e-mail, check the configuration.
To access configuration mode:
Unplug the equipment, plug it in again.
You will have 1 minute to connect and authenticate as you did from point 2 of this paragraph.
If once configured the indicator is in slow flashing green (on / off 1 time per second), and after 1
minute / 1.30 minute it changes to red and stays like that for about 10 seconds and restarts.
This indicates that it cannot connect to the Wi-Fi network. Either due to an error in the
configuration or a failure in the wifi to which it has to connect. Check the settings and the Wi-Fi
network is working properly. (To change the equipment in config mode, press the function
button for less than 2 seconds. The equipment will restart and the LED indicator will flash blue
to indicate that you can access the equipment)