INSTALLATION INSTRUCTIONS
C-LITE BULLET
C-FL-B-RDW, C-FL-B-RDN AND
C-FL-B-RDM LED SERIES
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou
votre code électrique local. Si vous n'êtes pas familier
avec ces codes et ces exigences, veuillez contacter un
électricien qualifié.
3.
Suitable for mounting within 1.2 m (4 ft) of the ground.
Peut être installé à moins de 1,2 m (4 pi) du sol.
4. Suitable for wet locations.
Convient aux emplacements mouilles.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
NOTES:
1. When mounting the fixture in an inverted position (1/2" fitter
above fixture), mount fixture to a watertight junction box and
cover. Also, caulk the conduit openings, around the junction box
cover, and the wire entry end of the 1/2" fitter with a high grade
caulking material, such as silicone rubber, to ensure water does
not enter fixture through 1/2" fitter.
http://lighting.cree.com/warranty
Document:
LPN00505X0001A2_A
Created By:
TMT
MOUNTING
1.
Do not wire fixture until fixture is mounted.
2.
This fixture can be mounted to any metal ½" NPSM (pipe size)
threaded mounting (supplied by others).
3.
Route fixture leads through the mounting hole.
4.
Thread mounting onto end of fitter on fixture and secure with
locknut. Using a sealing compound on the threads will ensure a
watertight seal.
5.
Complete the electrical connections (see "Fixture Wiring" below).
TO AIM FIXTURE
1.
Loosen the side bolt connected to the arm knuckle to aim the
fixture up or down. Re-tighten bolt to secure the fixture in the
desired position.
ELECTRICAL CONNECTIONS
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect supply ground to fixture ground (green or bare
copper) lead.
2. Connect supply common to fixture neutral (white) lead.
3. Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect supply ground to fixture ground (green or bare
copper) lead.
2. Connect supply L1 (Hot) to fixture neutral (white) lead.
3. Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
DIMMING
1. If 0/1-10V Dimming is used, connect the violet lead to the
supply positive dimming lead. For dimming, use Class 1 wir-
ing methods only. If dimming is not being used ensure to cap
off the violet lead.
2. If 0/1-10V Dimming is used, connect the grey or pink lead to
the supply negative dimming lead. For dimming, use Class 1
wiring methods only. If dimming is not being used ensure to
cap off the grey or pink lead.
|
866.924.3645
Date
9-15-2021