INSTALLATION INSTRUCTIONS
C-WP-A-ACWP Series
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
CAUTION- RISK OF FIRE
3.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
4.
Suitable for Wet Locations.
Adspte pour les Endroits Mouiles.
5.
Min. 90°C supply conductors.
Les fils d'alimentation 90°C min.
6.
WALL MOUNT ONLY.
INSTALLATION MURALE SEULEMENT.
7.
SUITABLE FOR OPERATION IN AMBIENT NOT
EXCEEDING 40°C.
8.
PEUT ETRE UTILISE A UNE TEMPERATURE
AMBIANTE N'EXCEDANT PAS 40°C.
9.
Class 1 wiring only.
Cablage de classe 1 uniquement.
10. MOUNTING ORIENTATION to indicate Diffuser end down
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
http://lighting.cree.com/warranty
Document:
LPN00875X0001A0_A
Created By:
TMT
MOUNTING OVER RECESSED JUNCTION BOX
NOTE: Knockouts are provided for mounting over a 3-1/2" or 4"
octagonal junction box or a single gang junction box.
1.
Remove lens assembly by loosening screws on side of frame.
Swing lens assembly open and slide lens assembly on hinges to
remove from mounting box. See Figure 1.
2.
Remove center plug from mounting box. See Figure 2.
3.
Drill out appropriate knockouts for chosen junction box. See
Figure 3.
NOTE: Fixture should not be exclusively supported by junction
box. Drill through appropriate knockouts in (3) locations around
perimeter of back box for additional support. See Figure 4.
4.
Pull supply leads from junction box through center hole in
mounting box. Attach mounting box to mounting surface at junction
box and at (3) mounting locations around perimeter of mounting
box. Customer supplied hardware appropriate for the mounting
surface should be used.
NOTE: A high grade caulking material, such as silicone rubber,
should be used between the three gaskets around perimeter of
the mounting box and the mounting surface and around perimeter
of the junction box gasket to prevent water entry into the fixture or
junction box.
NOTE: A bubble level is provided on mounting box to aid in
leveling box.
5.
Replace the lens assembly on hinges, but do not close.
6.
Use switch inside lens assembly to set desired color temperature.
See Figure 5.
NOTE: Power must always be OFF when adjusting color
temperature.
NOTE: Factory setting is 4K.
7.
Fixture is supplied with a photocell to switch the unit on at dusk
and off at dawn. If photocell control of fixture is not required,
disconnect photocell by unplugging connector from photocell. See
Figure 6.
8.
Rotate knob inside lens assembly to select desired wattage for
fixture. See Figure 7.
NOTE: Power must always be OFF when adjusting wattage.
NOTE: Factory setting is maximum wattage.
9.
Make wiring connections per the Electrical Connections section.
10. Swing lens into closed position. Retighten screws that were
loosened in Step 1 above.
FIGURE 1
Mounting Box
FIGURE 2
|
866.924.3645
Date
01-11-2023

Publicidad

loading

Resumen de contenidos para C-LITE C-WP-A-ACWP Serie

  • Página 1 Document: LPN00875X0001A0_A Date 01-11-2023 INSTALLATION INSTRUCTIONS Created By: C-WP-A-ACWP Series MOUNTING OVER RECESSED JUNCTION BOX NOTE: Knockouts are provided for mounting over a 3-1/2" or 4" octagonal junction box or a single gang junction box. Remove lens assembly by loosening screws on side of frame. Swing lens assembly open and slide lens assembly on hinges to remove from mounting box.
  • Página 2 Document: LPN00875X0001A0_A Date 01-11-2023 INSTALLATION INSTRUCTIONS Created By: C-WP-A-ACWP Series FIGURE 4 MOUNTING USING CONDUIT Remove lens assembly by loosening screws on side of frame. Swing lens assembly open and slide lens assembly on hinges to remove from mounting box. See Figure 1. Remove appropriate conduit plug from back wall or side of mounting box.
  • Página 3 Document: LPN00875X0001A0_A Date 01-11-2023 INSTALLATION INSTRUCTIONS Created By: C-WP-A-ACWP Series FCC NOTICE ELECTRICAL CONNECTIONS CAUTION: Changes or modifications not expressly approved Fixture is equipped with universal volt driver 120-277V could void your authority to use this equipment. (ie. 120V, 208V, 240V or 277V) This device complies with part 15 of the FCC Rules.
  • Página 4 Documento: LPN00875X0001A0_A Fecha 11-01-2023 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-A-ACWP INSTALACIÓN SOBRE UNA CAJA DE CONEXIONES EMPOTRADA NOTA: Incluye orifi cios precortados para instalarse sobre cajas de conexiones octogonales de 3,5” (89 mm) y 4” (101 mm) o una caja de conexiones de una sola toma.
  • Página 5 Documento: LPN00875X0001A0_A Fecha 11-01-2023 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-A-ACWP FIGURA 4 MONTAJE USANDO CONDUCTO Retire el conjunto del lente afl ojando los tornillos en el costado del marco. Deslice el conjunto del lente para abrirlo y deslice el conjunto del lente sobre las bisagras para retirar la caja de montaje.
  • Página 6 Documento: LPN00875X0001A0_A Fecha 11-01-2023 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-A-ACWP AVISO DE LA FCC CONEXIONES ELÉCTRICAS La luminaria está equipada con un controlador de voltaje universal de 120-277 V (es decir, 120 V, 208 V, 240 V o 277 V). PRECAUCIÓN: Los cambios o las modifi...
  • Página 7 Document : LPN00479X0001A0_A Date 11-01-2023 INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-A-ACWP INSTALLATION SUR UNE BOÎTE DE JONCTION ENCASTRÉE REMARQUE : Des alvéoles défonçables sont prévues pour le montage sur une boîte de jonction octogonale de 89 mm (3½ po) ou de 102 mm (4 po), ou une boîte de jonction simple.
  • Página 8 Document : LPN00479X0001A0_A Date 11-01-2023 INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-A-ACWP FIGURE 4 INSTALLATION UTILISANT UN CONDUIT Retirez l’assemblage lentille en desserrant les vis sur le côté du cadre. Ouvrez l’assemblage lentille en le faisant pivoter et faites glisser l’assemblage lentille sur les charnières pour le retirer de la boîte de montage.
  • Página 9 Document : LPN00479X0001A0_A Date 11-01-2023 INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-A-ACWP AVIS DE LA FCC RACCORDEMENTS ÉLECTRIQUES Le luminaire est équipé d’un pilote de tension universelle de 120 à 277 V MISE EN GARDE : Des modifi cations ou changements non (c’est-à-dire, 120 V, 208 V, 240 V ou 277 V) expressément approuvés pourraient annuler votre autorisation d’utiliser cet équipement.