M.-Nr. 09149681
The "Miele Service Documentation (MSD)" service application is required when carrying out maintenance work
on the appliance
The safety instructions and warnings in the Miele Service Documentation (MSD) for the corresponding model must be
observed.
Work on the appliance must be carried out in accordance with the work instructions.
Installing module for liquid dispensing
A
Remove the machine lid; see the model-specific TSD.
A
For each dispensing pump saw off a connection stub on the mixer box to suit the internal diameter of the hose.
When doing so start from underneath. See Fig. 1.
A
Use a 4 mm drill bit to drill a hole in the cut-off stub. See Fig. 1
A
Push hose (1) onto the connection stub, and secure it with a hose clip (2). See Fig. 1.
A
If using a non-return valve cut the hose before the connection stub.
A
Connect both ends of the hose to the non-return valve and tighten the nuts. Observe the direction of flow in the non-
return valve. See Fig. 2.
A
Install dispensing pump housing DOS-G2 in its intended location (e.g. the DOS-S dispensing pump rack). See Fig. 3.
A
Fit counter nuts to the cable feed-throughs (1) and (2) in the base of the DOS-G2 dispensing pump housing.
See Fig. 4.
A
Close superfluous openings (3) with stoppers. See Fig. 4.
A
Connect the connection cable to the dispensing pump and suction lance according to the wiring diagram.
A
Fit the dispenser pumps DOS-P2 in the dispenser pump housing DOS-G2 and screw them in position. See Fig. 5.
A
Connect the hoses to the dispensing pumps with hose clips.
A
If using less than 3 DOS-P2 dispensing pumps, the vacant pump slot should be closed with the cover provided.
A
Fit the casing lid with 3 self-tapping screws onto the dispensing pump housing DOS-G2.
NOTE
Electromagnetic radiation
Damage to electrical appliances
A
The connection cables for the dispensing pumps and suction lances must be laid separately in order to avoid
interference in the control circuit (electromagnetic compatibility). For safety reasons the connection cables must
not exceed 4.5 m in length.
A
Pass the connection cables through the cable throughfeeds on the connection strip to the built-in multifunction
module and connect them.
A
Refit the machine lid.
A
Connect the machine to the power supply and switch it on.
A
Reconnect the machine to the gas supply if there is one and it has previously been disconnected.
A
Carry out appropriate electrical safety and functional tests.
A
Carry out a functional check only with the dispensing pump system primed and filled.
en
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
9 von 26
18.01.2022