Installation
IMPORTANT : Please follow the safety advice set out on pages 3 to 4.
- DO NOT wire/fit a plug to this appliance. The appliance
must be electrical connected to a fused fixed spur, which
is fitted with a 13Amp fuse.
- All fittings must be installed by a competent person in
accordance with the current IET Wiring Regulations
(BS7671). If in doubt, consult a qualified electrician.
- This product is suitable for use in living areas, and
Bathroom (dry) Outside Volume only (see diagram below
and current IET Wiring Regulations for details). It is not
suitable for Bathroom Volumes 0, 1 and 2. If being fitted in
a bathroom a 30mA RCD must be used. This appliance
does not come fitted/supplied with a fused plug.
- Always refer to the Reference Drawing for Bathroom
Installation.
Note : the below drawing is for reference only.
Outside volume
Ground
Finished floor
- Full details can be found in the current IET Wiring
Regulations (BS7671).
Volume 2
Volume 1
0,60 m
Volume 0
Hidden volume
19