Descargar Imprimir esta página
Frigidaire FLCE7523AW Instalación
Frigidaire FLCE7523AW Instalación

Frigidaire FLCE7523AW Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Installation
*Please refer to the Use & Care instruction booklet provided with this laundry center for further details.
WARNING - RISK OF FIRE
• Ensure the entire dryer exhaust system is clean and free of lint and debris prior to the
installation of your new laundry center. The entire exhaust system should be inspected and
cleaned a minimum of every 18 months with normal usage. Failure to comply with cleaning
your exhaust system will increase the RISK of FIRE.
• DO NOT install a clothes dryer with flexible plastic or flexible foil venting material. Flexible
venting materials are known to collapse, be easily crushed and trap lint. These conditions will
obstruct clothes dryer airflow and increase the risk of fire.
• DO NOT screen the exhaust ends of the vent system, or use any screws, rivets or other
fasteners that extend into the duct to assemble the exhaust system. NO screen or grate of
any mesh size is allowed to cover the outdoor exhaust opening.
• Install the laundry center according to the manufacturer's instructions and local codes.
• Laundry Center installation and service must be performed by a qualified installer, service
agency or the gas supplier.
• The electrical service to the dryer must conform with local codes and ordinances and the
latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian
Electrical Code CSA C22.1 part 1.
• The laundry center is designed under UL 2158 - CAN/CSA C22.2 No. 112 (latest editions) for
HOME USE only. This laundry center is not recommended for commercial applications such as
restaurants, beauty salons, etc.
• Destroy the carton and plastic bags after the laundry center is unpacked. Children might use
them to play. Cartons covered with rugs, bedspreads, or plastic sheets can become airtight
chambers causing suffocation. Place all materials in a garbage container or make materials
inaccessible to children.
The instructions in this manual and all other literature included with this dryer are not meant to
cover every possible condition and situation that may occur. Good safe practice and caution MUST
be applied when installing, operating and maintaining any appliance.
1
Installation Checklist
Shipping hardware
Exhaust venting
‰ Free-flowing, clear of lint buildup
‰ Foam shipping restraint (inside wash tub)
removed and stored
‰ End of exhaust vent securely fastened
to exhaust port to prevent air leaks and
‰ Foam shipping support (underneath
excess noise
appliance) removed and stored
‰ 4 inch (102 mm) rigid or semi-rigid
Leveling
ducting of minimal length and turns
‰ Laundry center is level, side-to-side and
‰ NO foil or plastic venting material
front-to-back
‰ Approved vent hood exhausted to
‰ Cabinet is setting solid on all corners
outdoors
Water supply
240V electric supply
(electric dryer)
‰ Use only new hoses and verify rubber
sealing washers are installed
‰ Approved NEMA 10-30R or 14-30R
service cord with all screws tight on
‰ HOT supply is connected to HOT inlet and
terminal block
COLD supply is connected to COLD inlet
‰ Approved strain relief installed
‰ HOT and COLD water supply turned on
‰ Terminal access cover installed before
‰ No leaks present at water supply
initial operation
connections or appliance inlet connections
Electrical power
-recheck in 24 hours
‰ House power turned on
Drain
‰ Laundry Center plugged in
‰ Stand pipe or wall drain height min. 33"
Final checks
‰ Drain hose secured in place with cable tie
‰ Installation Instructions and Use & Care
(shipped in drum)
instruction read thoroughly
‰ Water enters drum when cycle starts with
lid lowered and dryer door latches and
For detailed information, refer to the
drum tumbles when cycle starts
Use & Care instruction provided with
this laundry center.
‰ Registration card sent in
A17468404 (2109)
for Frigidaire Laundry Center
*
2
Electrical requirements
Electric dryer
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or circuit
breakers.
POWER SUPPLY - 3-wire or 4-wire, 240 volt,
single phase, 60 Hz, Alternating Current. The
power cord is NOT supplied with unit.
OUTLET RECEPTACLE - NEMA 10-30R or
NEMA 14-30R receptacle to be located so
the power supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See "Grounding
requirements" in Use & Care instructions. The
laundry center MUST be grounded. In the
event of malfunction or breakdown, grounding
will reduce the risk of electrical shock by a
path of least resistance for electrical current.
WARNING
Improper connection of the equipment grounding conductor can cause an electrical shock that
may result in serious injury or death. Check with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
3
Connect or Construct Vent Exhaust
Use only 4 inch rigid or semi-rigid metal
ducting
Clean lint from duct system
Use only metal foil tape to connect ducts (no
screws)
of 4" (102 mm) Rigid Metal Duct
LONG VENT MODELS ONLY FLCE7523AW
4" (10.2 cm) louvered
0
127 ft. (39 m)
1
117 ft. (35 m)
2
107 ft. (32 m)
3
97 ft. (29 m)
4
87 ft. (26 m)
DO NOT exceed 8 ft. (2.4m) total duct length if installing semi-rigid venting.
DO NOT install flexible plastic or flexible foil ducting material.
For detailed information, refer to the Use & Care instruction provided with
this laundry center.
For support in the U.S. call 1-877-4ELECTROLUX (1-877-435-3287) or visit www.electroluxappliances.com. For support in Canada call 1-800-265-8352 or visit www.electroluxappliances.ca.
Since your laundry center is equipped with
a power supply cord having an equip-
ment-grounding conductor and a grounding
plug, the plug MUST be plugged into an appro-
priate, copper wired receptacle that is properly
installed and grounded in accordance with all
local codes and ordinances or in the absence of
local codes, with the National Electrical Codes,
ANSI/NFPA 70 (latest edition), or in Canada,
the Canadian electrical code C22.1 part 1. If in
doubt, call a licensed electrician.
DO NOT cut off or alter the grounding prong on
the power supply cord. In situations where a
two-slot receptacle is present, it is the owner's
responsibility to have a licensed electrician
replace it with a properly grounded three prong
grounding type receptacle.
ELECTRICAL SHOCK HAZARD
WARNING
FIRE HAZARD
Never exceed more than four-90˚ elbows in
the exhaust duct system.
Use 4" (10.2 cm) clamp to connect dryer &
exhaust system
Use 90° quick-turn elbow to vent left or right
from dryer
MAXIMUM LENGTH
VENT HOOD TYPE
Correct
2.5" (6.35 cm)
124 ft. (37 m)
Exhaust system must
NO screen or grate
be vented outside with
114 ft. (34 m)
of any mesh size is
approved vent hood.
104 ft. (31 m)
allowed to cover the
exhaust opening.
94 ft. (28 m)
84 ft. (25 m)
Incorrect
TO INSTALLER:
4
Connect to Water Line and Drain
Connecting to the water line
1. Run some water from the hot and cold
faucets to flush the water lines and remove
particles that might clog the water valve
screens and to determine which faucet is
hot and which is cold supply.
2. Check to ensure that the inlet hoses have
the rubber washer firmly in place. Use only
new hoses.
3. Connect the HOT inlet hose to the HOT inlet
connection on the washer and the COLD
inlet hose to the COLD inlet connection
on the washer (cold on top). Tighten by
hand until snug. Then tighten each supply
connection another 2/3 turn with pliers.
DO NOT cross thread or over-tighten these
connections.
For detailed information, refer to Use & Care instruction provided with this
laundry center.
5
Connect to Gas or Electric
WARNING
ELECTRICAL SHOCK HAZARD
A U.L. approved strain relief must be
installed onto power cord. If the strain relief
is not attached, the cord can be pulled out of
the dryer and can be cut by any movement
of the cord, resulting in electrical shock.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT use an aluminum wired receptacle
with a copper wired power cord and plug
(or vice versa). A chemical reaction occurs
Correct
between copper and aluminum and can
cause electrical shorts. The proper wiring and
receptacle is a copper wired power cord with a
copper wired receptacle.
6
Level and Connect
Incorrect
1. Use adjustable pliers to adjust the leveling legs so the laundry center is
level front-to-rear and side-to-side, and stable corner-to-corner
2. Connect power.
IMPORTANT
Please review "Troubleshooting" in your Use & Care instruction before calling for service.
For detailed information refer the Use & Care instruction provided with
this laundry center.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Leave these instructions with the customer.
4. Connect the HOT inlet hose to the HOT
water supply and the COLD inlet hose to the
COLD water supply. Tighten by hand until
snug. Then tighten each supply connection
another 2/3 turn with pliers. DO NOT bend,
kink, or pinch water inlet hoses.
5. Turn on the water and check for leaks.
Connecting to the drain
1. Form a "U" shape on the end of the drain
hose with the hose pointed toward the
drain.
2. Place the formed end in a laundry tub or a
standpipe and secure the drain hose with
the cable tie (provided in the enclosure
package) to the standpipe, inlet hose,
laundry tub, etc. so the hose does not pull
out from the force of the water.
Electric Dryer
30 AMP
30 AMP
Move
White Wire
Don't Move
White
White Wire
Wire
Green
Wire
Black
or
Red
Wire
Install
U.L.-Approved Strain Relief
For detailed information, refer to the
Use & Care instruction provided with
this laundry center.

Publicidad

loading

Resumen de contenidos para Frigidaire FLCE7523AW

  • Página 1 4” (102 mm) Rigid Metal Duct outdoors cause electrical shorts. The proper wiring and For detailed information, refer to the LONG VENT MODELS ONLY FLCE7523AW Water supply 240V electric supply receptacle is a copper wired power cord with a Use &...
  • Página 2 Instalación para centro de lavado Frigidaire AL INSTALADOR: Deje estas instrucciones con el cliente. *Consulte el folleto de Guía de Uso y Cuidado suministrado con el centro de lavado para obtener información más detallada. ADVERTENCIA: PELIGRO DE INCENDIO Requisitos del sistema de eléctrica Conecte el suministro de agua y desagüe...
  • Página 3 Installation de votre combinaison laveuse/sécheuse Frigidaire Laissez ces instructions au client. POUR L’INSTALLATEUR : *Veuillez consulter les Guide d’utilisation et d’entretien fourni avec cette votre laveuse/sécheuse pour plus de détails. Exigences électriques AVERTISSEMENT-RISQUE D’INCENDIE Raccordement de l’eau et de l’évacuation Sécheuse électrique...

Este manual también es adecuado para:

Flce7522awFlcg7522aw