stand-by status. Under 5-minute stand-by status,
the machine can fog immediately upon switched
ON, and no need to wait 30~45 seconds to heat up.
This function can save unnecessary power con-
sumption.
Note
The machine must be operated with the at-
tached controller.
30-45 seconds after switching on the fogging
button of the controller under cold status, it
starts fogging automatically.
Switched on and then off the fogging button
of the controller immediately, the machine
5. VERY IMPORTANT
35 seconds after the machine empties liquid, the
pump and the heater stop working, and the lit red
LED flashes slowly to remind of adding liquid. After
adding liquid, the machine cannot withdraw auto-
matically from the status of no liquid. Just switch
the controller to OFF to withdraw from the status of
no liquid, and enter normal status.
6. TROUBLESHOOTING
This troubleshooting guide is meant to help solve
simple problems. If a problem occurs, carry out the
steps below in sequence until a solution is found.
Once the unit operates properly, do not carry out
following steps. If the problem persists, refer servic-
ing to a qualified technician.
P. 6
Neo Steam 450 Infinite - English version
will heat up automatically until it can fog and
will keep stand-by status for 5 minutes. During
the period between 35 seconds after being
switched on and 5 minutes, the machine can
fog any time, but mains power must be on.
If only plug mains power, but not switch the
button of controller to "ON", the machine will
not heat up.
Self-cleaning function: After each fogging, it
is suggested to shot down the power always in
2 minutes to clear the tubing of the remaining
liquid. This helps to have better fogging effect
next time.
Power Connected but No Fog Is Emitted
1. Check the power supply. Plug the unit into
grounded electric power supply socket with
proper voltage.
2. Check your controller if in correct connection.
3. Disconnect fog machine from electric power
supply. Replace fuse with one of the same type.