NEO STEAM 450 INFINITY Manual De Usuario página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Other Abnormal Situations
LED indicator on rear of the machine has the follow-
ing 3 functions:
1. When the machine is under normal status, the
LED keeps lighted.
2. When the machine is under status of empty
liquid, the LED flashes slowly.
3. When the machine is under abnormal status,
or too high temperature, the LED flashes fast.
When the LED flashes fast, the pump and the
7. MAINTENANCE
Before doing maintenance, please make sure that
the power is cut, the power cord is unplugged, and
the machine itself has cooled down. The mainte-
nance must be done by qualified person.
The fog liquid is not allowed to get dirty. Be
sure to always clean or replace the caps on the
fog liquid vessel and tight the cover of the fog
machine liquid tank immediately after filling.
Periodically check the connections among
the oil tube, the pump and the heater to see
if there's oil leaking. If positive, lock tight the
connections carefully with proper tool.
PC board should be kept from being dirtied
with oil. In case this happened, dismantle care-
fully the PCB, and have it brushed clean both
sides with dilute alcohol. Leave it dry itself,
then install it back. Make sure all wires are well
connected.
Clean the metal cover with dry cloth.
heater will stop working. This means two possi-
ble situations:
(1) Temperature of the heating pipe is too high.
The machine is doing auto-adjustment, and will
get repair itself within 30 seconds.
(2) The machine has something wrong, and can-
not repair itself. Shut down to cool it, and bring
unit to your local agent or appointed service
place for inspection, prohibit any dismantle-
ment by yourself.
English version
- Neo Steam 450 Infinite
P. 7

Publicidad

Tabla de contenido
loading

Tabla de contenido