Please read these instructions thoroughly, before using the pump!
This appliance is not suitable for use by persons (including children) with limited physical, sensory or mental
capabilities or lacking experience and/or knowledge, except if they are supervised by a person responsible
for their safety or have been instructed in the use of the appliance.
Children should be supervised in order to make sure that they do not play with the appliance.
Use
Centrifugal pump for submersible usage with resin encapsulated motor.
The pumps are designed for use in water, for instance: garden pond, fi sh pond, fountain, terrace fountain,
indoor fountain, for operating fi lters systems, watercourses etc. as well as for aerating and recirculating
water.
Please refer to the type plate for technical specifi cations or the table on page 1.
Safety measures
- Caution! It may only be used in garden ponds and in their protection area if the electrical installations
have been set up to comply with the code's requirements. Please contact an electrician.
- Before use: Check whether mains connection and plug are intact.
- Mains voltage and type of current have to correspond to the data on the type plate.
- The pump has to be connected to a regular safety plug socket through a residual current device
(RCD, 30 mA).
- The connection box should be located in a water-protected area. It should be at least 2 m away from the
edge of the pond (see fi g.1).
- Keep the plug dry!
- Pull out mains plug before starting to work on the pump, fountain or pond. It is not allowed to run
the pump when people are inside the water (disconnect the pump)!
- Important! If the mains connection or the motor housing is damaged, the pump cannot be used anymore.
It cannot be repaired since the connection is cast into the motor housing.
- Never hang up or transport the pump by the cable!
- Operate the pump only when it is immersed in water!
Start-up (see fi g.1)
Important! Do not let the pump run dry. This could cause damage to the appliance.
- Immerse the pump completely in your pond. This causes the pump body to be fi lled with water.
- A minimum water depth of 20 cm is required for underwater operation to avoid the pump taking in air.
-
The maximum depth for submerged operation of the
pump is 2 m!
2 m
- The water temperature should not exceed 35°C.
- Do not let the pump freeze in the wintertime.
- The pump is switched on by putting the plug in the socket.
- To prevent the pump becoming unnecessarily dirty, place it above the mud in your pond, in a fi rm and
horizontal position (on a brick)!
- A range of accessories may be fi tted onto the threaded connection of the pump.
- Running in conjunction with fountain jets, the pump should be positioned fi rmly and horizontally (on a
brick).
Dismantling / Assembly (see fi g. 2 - 4)
1.
Follow the safety measures. Disconnect the pump!
2.
Push in the two brackets on the front of the pump, push the top shell (1) up and remove it.
3.
Lift the entire pump (8) out of the bottom shell (2).
4.
Turn the lid (4) counterclockwise through approx. 20° in the oppposite direction to the stop.
5.
Remove the lid (4) from the pump (8).
6.
Remove the complete rotor (5) from the pump (8). The shaft of the rotor (5) is mounted on two rubber
bearings in the pump (8) and in the lid (4).
7.
The complete rotor (5) can be made to rotate on the shaft.
8.
Clean all parts using clear water so that they may be moved very easily. Do avoid using any sharp
instruments.
9.
Re-assemble the pump as follows:
9.1. Replace complete rotor (5) in the pump (8). Make sure the rubber bearings are seated correctly in the
pump (8) and the lid (4).
9.2. Fit turned lid (4) onto the pump (8) and turn it clockwise until stop.
9.3. Place the pump (8) into the bottom shell (2).
9.4. Rest the top shell (1) against the two rear hooks on the bottom shell (2) and snap it into the front
brackets.
To ensure proper functioning, repeat the above procedure frequently, depending on clogging and working
time.
8
Maintenance
In order to prolong the service life of your pump and to keep it in good operating condition, it is
recommended to carry out maintenance and cleanup regularly. This can be done by everyone, quickly and
easily. See „Dismantling/Assembly"
Servicing intervals
- In the beginning check performance of your pump every day. If necessary, clean the fi lters.
- Since servicing intervals (complete cleanup) will vary depending on pond pollution, repeat the periodic
service to your pump in accordance with the requirements given.
Should you determine that there are damaged or worn parts, do replace them. See „Spare parts".
Winter / Pump care
Protect your pump from freezing-in!
Take the pump out of your pond in autumn.
Clean the pump completely following the outlined instructions.
During the winter months store the pump in a frost-resistant room.
Spare parts
For ordering spare parts, please indicate the pump type, the designation and the Art.-No. as per table below
(see also fi g. 2 - 4).
Item
Designation
Pump Type
1
Upper shell
system-X 750, system-X 1000
2
Lower shell
system-X 750, system-X 1000
3
Handle
system-X 750, system-X 1000
4
Rotor
system-X 750
system-X 1000
5
Inlet cover
system-X 750, system-X 1000
6
Distance C0
system-X 750, system-X 1000
7
Accessories
system-X 750, system-X 1000
Warranty conditions
This pump is covered for warranty claims for a period of 36 months, beginning on the day of supply. The
date in the proof of purchase document denotes the authoritative day of supply. In case of damage caused
by material or processing faults which arises during the warranty period, we shall repair or replace the item
free of charge. In each case we shall elect whether to repair or replace the item. Damage which is caused
by installation and operating errors, lime deposits, insuffi cient care, frost, normal wear or improper attempts
to perform repairs are not covered by this warranty.
Spare parts, such as rotors, impellers, lighting accessories etc.
are subject to normal wear or have a certain service life due to their design. They are therefore not covered
by the warranty. The warranty will be rendered null and void if any modifi cations are made to the pump, e.g.
cutting off the mains connection cable or the mains plug.
We shall not be liable for any consequential damages caused by failure of the pump or improper operation.
For all warranty claims please return the device to us together with proof of purchase, carriage paid and at
your own transportation risk.
Waste disposal
Waste disposal of electronic devices by the user in private households of the EU
It is not allowed to dispose the product along with the regular waste disposal, instead it has to be collected
separately. It is your responsibility to dispose and recycle the device in a proper place and protect the
environment through this. More information, where to dispose your devices can be obtained at the local
departments.
9
Art-No.
104 / 003661
104 / 003662
104 / 003663
168 / 009071
168 / 009092
168 / 009150
104 / 003834
104 / 003957

Publicidad

loading

Este manual también es adecuado para:

System-x 1000