A-6. Environmental Requirements; A-7. Reliability - Oki OKIPOS 407 Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 91

A-6. Environmental Requirements

(1) Operating
Temperature
Humidity
(%RH)
90
80
60
40
20
10
(2) Transport/storage (except for paper)
Temperature
Humidity

A-7. Reliability

(1)MCBF
(2) Cutter life
5°C to 45°C
10% to 90% RH (without condensation)
Operating environment
range
0
10
20
Temperature (°C)
Operating temperature and humidity range
-20°C to 60°C
10% to 90% RH (without condensation)
60 million lines (based on an average printing rate of
12.5% with paper thickness in the range 65 µm to 75 µm)
25 million lines (based on an average printing rate
of 12.5% with paper thickness in the range 76 µm to
150 µm)
1.0 million cuttings (if the paper thickness is between
65 and 100 µm)
0.30 million cuttings (if the paper thickness is be-
tween 100 and 150 µm)
– 125 –
34°C90% RH
40°C65% RH
45°C50% RH
30
40
50

Publicidad

Tabla de contenido
loading