LiftMaster K29-32410 Manual página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL THE NEW DC ALARM
1. Insert the provided alarm flange onto the
chassis using the mounting holes that held
the old alarm.
2. Mount the alarm in the flange (Figure 3).
a.
Remove the plastic nut from the alarm.
b. Insert the alarm through the flange.
c.
Secure the alarm to the flange with the
plastic nut.
3. Use a provided wire tie to secure the wires
from the alarm to the body of the alarm as
shown to prevent the wires from being
tangled in the sprocket.
4. Route the wire harness to the main board
following the same path as the old harness.
Connect the red wire to J1-16, and the black
wire to J1-12. Polarity is important (see
illustration). If NOT connected with correct
polarity, the alarm will be damaged (Figure
4).
5. Use the wire ties provided to secure the
harness.
6. Connect the provided blue wire between J1-3
and J1-15 (Figure 4).
7. Restore power to the operator.
FIGURE 4
J1 TERMINAL BLOCK
FIGURE 3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Plastic nut
Operator chassis
TB1 TERMINAL BLOCK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
J1 TERMINAL BLOCK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Black wire (-) from alarm
2
Flange
Blue wire
TB2 TERMINAL BLOCK
Black wire from alarm
Blue wire
Blue wire
Red wire (+) from alarm
Red wire from alarm
Wire tie
Alarm
Wire harness

Publicidad

Tabla de contenido
loading

Tabla de contenido