1. About this document

Please read carefully and keep in a safe place.
– Under copyright. Reproduction either in whole or in
part only with our consent.
– Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
Reference to other information in
the document.
...

2. General safety precautions

Disconnect the power supply before
!
attempting any work on the unit.
• During installation, the electric power cable to be
connected must not be live. Therefore, switch off the
power first and use a voltage tester to make sure the
wiring is off-circuit.
• Installing the sensor-switched light involves work on
the mains voltage supply.
This work must therefore be carried out by a qualified
electrician in accordance with applicable national
wiring regulations and electrical operating conditions.
(e. g. DE - VDE 0100, AT - ÖVE-ÖNORM E8001-1,
CH - SEV 1000 )
• Only use genuine replacement parts.
• Repairs and battery changes must only be carried
out by specialist workshops.
• The emergency-light system must be installed in
compliance with national regulations and regularly
tested for proper working order.
3. RS PRO Connect 5100/5150 SC
RS PRO Connect 5100/5150 SC EM
RS PRO Connect 5100/5150 C
Proper use
RS PRO Connect 5100/5150 SC
– Sensor-switched luminaire with active motion
detector also suitable for installing in rooms exposed
to moisture.
– Limited suitability for outdoor use as a result of
detection sensitivity.
Note:
Make sure that the light is installed at a minimum dis-
tance of 3 m from any Wi-Fi routers or Access Points.
Proper use
RS PRO Connect 5100/5150 SC EM
– Sensor-switched light with active motion detector also
suitable for installing in rooms exposed to moisture.
– Limited suitability for outdoor use as a result of
detection sensitivity.
– Integrated emergency light (EM).
Proper use
RS PRO Connect 5100/5150 C
– Light without active motion detector also
suitable for installing in rooms exposed to moisture.
Suitable for use in an environment in which
conductive dust is expected to settle on the
light.
How sensor-switched lights work
The integrated HF sensor emits high-frequency electro-
magnetic waves (5.8 GHz) and receives their echo.
The change in echo caused by the slightest movement
within the light's detection zone is detected by the
sensor.
A microprocessor then issues the switch command
"switch light ON". Detection is possible through doors,
panes of glass or thin walls.
Note: The high-frequency power of the HF sensor is
approximately 1 mW – 1000 times less than the trans-
mission power of a mobile phone or microwave oven.
How lights work
Light without sensor. This functions for the C model are
only applicable in combination with a Bluetooth-capa-
ble device.
How emergency light works
In the event of a power failure, the emergency light (EM)
switches on automatically for 3 hours in accordance
with regulation EN 60598-2-22.
Package contents RS PRO Connect 5100/5150 SC /
RS PRO Connect 5100/5150 SC EM (Fig. 3.1)
– Sensor-switched indoor light
– 2 mounting clips
– 2 slot-in shrouds
Package contents RS PRO Connect 5100/5150 C
(Fig. 3.2)
– Indoor light
– 2 mounting clips
Product dimensions RS PRO Connect 5100
(Fig. 3.3)
Product dimensions RS PRO Connect 5150
(Fig. 3.4)