Product components
RS PRO Connect 5100/5150 SC /
RS PRO Connect 5100/5150 SC EM (Fig. 3.5)
A
Screwed cable gland
B
Twist lock
Connecting terminal
C
D
Mounting clamp
E
End caps
F
Light enclosure
G
HF sensor
Slot-in shroud
H
Product components
RS PRO Connect 5100/5150 C (Fig. 3.6)
Screwed cable gland
A
B
Twist lock
C
Connecting terminal
D
Mounting clip
End caps
E
F
Light enclosure
Detection zones for ceiling mounting Ø 1-10 m
(Fig. 3.7)
Detection zones for wall mounting Ø 1-10 m (Fig. 3.8)
Luminous intensity distribution: (Fig. 3.9 - 3.14)

4. Electrical connection

Wiring diagram (Fig. 4.1)
The supply lead consist of three wires:
L
= phase conductor (usually black, brown or grey)
N
= neutral conductor (usually blue)
E
= protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using a
voltage tester; then disconnect from the power supply
again. Connect phase (L), neutral conductor (N) and
protective-earth conductor (E) to the plug-in terminal.
Important:
Incorrectly wired connections will produce a short
circuit later on in the product or your fuse box. In this
case, you must identify the individual conductors once
again and reconnect them.
A mains power switch for turning the unit ON and OFF
may of course be installed in the mains supply lead.
Note: The light source of this light cannot be replaced.
If the light source needs to be replaced (e.g. at the end
of its service life), the complete light must be replaced.
5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• When installing the sensor-switched light, make sure
the installation site is not exposed to vibration.
• Select an appropriate mounting location, taking the
reach and motion detection into consideration.
Note: for wall mounting, the light must be installed
horizontally.
Mounting procedure
• Switch OFF power supply (Fig. 4.1)
• Mark drill holes (Fig. 5.1)
• Drill holes and insert wall plugs (Fig. 5.2)
• Screw on mounting clips (Fig. 5.3)
• Fit light enclosure (Fig. 5.4)
• A click confirms proper engagement
• Open screwed cable gland and twist lock (Fig. 5.5)
• Guide connecting cable through screwed cable
gland and twist lock and connect to plug-in terminal
(Fig. 5.6)
• Close screwed cable gland and twist lock (Fig. 5.7)
• Switch ON power supply (Fig. 5.7)
6. Function
Factory settings (as delivered)
– Reach setting:
– Main light time setting:
– Basic light time setting:
– Twilight setting:
– Basic light dimming level:
Please refer to the technical documentation at:
www.steinel.de to put the product into reference mode.
To configure the light, you must download the STEINEL
Connect app from your app store. You will need a
Bluetooth-capable smartphone or tablet.
Android
If the light is not configured with the app, it will work as
an independent sensor-switched light with the given
factory settings.
– 16 –
max.
10 sec.
1 min
2000 lux
50%