Troubleshooting - Hilti AG 125-A22 Manual De Instrucciones

Ocultar thumbs Ver también para AG 125-A22:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
8.2 Maintenance
WARNING
Do not operate the tool if parts are damaged or
when the controls do not function faultlessly. Have
the power tool repaired by Hilti Service.
WARNING
en
Repairs to the electrical section of the power tool
may be carried out only by trained electrical spe-
cialists.

9. Troubleshooting

Fault
The battery runs down more
quickly than usual.
The battery doesn't engage
with an audible click.
LED 1 blinks
The power tool doesn't run
and 1 LED blinks.
The power tool doesn't work
and all 4 LEDs blink.
The battery becomes too hot
to touch.
The power tool doesn't
achieve full power.
36
Printed: 31.07.2012 | Doc-Nr: PUB / 5071441 / 000 / 00
All manuals and user guides at all-guides.com
Possible cause
Battery condition is not optimal.
The retaining lugs on the battery
are dirty.
The battery is discharged.
The power tool has
been overloaded
(application limits exceeded).
The battery is discharged.
The battery is too hot or too cold.
The power tool has been over-
loaded briefly.
The overheating prevention cut-out
has been activated.
The battery cells are defective.
A battery with inadequate capacity
was used.
Check all external parts of the power tool for damage
at regular intervals and check that all controls operate
faultlessly.
8.3 Checking the power tool after care and
maintenance
After carrying out care and maintenance work on
the power tool, check that all protective and safety
devices are fitted and that they function faultlessly.
Remedy
Have battery condition diagnosed
by Hilti Service or replace with a
new battery.
Clean the retaining lugs and check
that the battery engages securely.
Contact Hilti Service if the problem
persists.
Charge the battery.
Use the right power tool for the job
(don't use a low-powered tool for
heavy work).
Change the battery and recharge
the discharged battery.
Bring the battery to the recommen-
ded working temperature.
Release the switch and press it
again.
Allow the power tool to cool down.
Place the tool in non-flammable
surroundings (at least 3 meters
away from flammable materials)
where it can be kept under obser-
vation and allow it to cool down. If
necessary, extinguish flames with
cold water or allow it to burn under
supervision. Contact Hilti Service.
Use a battery with a capacity of at
least 2.6 Ah.

Publicidad

Tabla de contenido
loading

Tabla de contenido