5.1.7 Do not keep the stacker work with load continuously to prevent the motor burned.
5.1.8 When moving the stacker, the clearance between the fork and ground should be more then 200mm.
5.1.9 In order to keep the stability of stacker should move slowly and the distance is short to the full when
stacking the load.
5.1.10 To ensure the safety, turn the switch to OFF, low down the stacker and take away the switch key after
operation.
5.2 How to use charger
5.2.1 After continuous working, the battery will be low in power. The red light <3 graduation on coulome-
ter is showing and lifting speed slow down obviously, it must be recharged. If not, it will shorten the service
life of electric pump and battery.
5.2.2 Before recharging the battery, please carefully read and fully understand the attached instruction manual
of charger.
5.2.3 Before plugging the charger into a power socket. Make sure local electric power matches the charger.
Turn off the switch,then connect the charger to socket in the electric control box, the battery will be recharged
automatically.
5.2.4 When the battery is fully charged, the charging indicator will show
100%.
5.2.5 When charging, there will separate out hydrogen and oxygen. So please
keep ventilated and away from the fire in case of danger.
6. Daily Maintenance & Periodical Inspection
6.1 Inspect the each section for loose bolts and nuts monthly.
6.2 Inspect the each section, wheel, hydraulic system, electric pump for distortion, worn, and abnormal noise
monthly.
6.3 Inspect performance of lifting and lowering the fork and other device monthly.
6.4 Inspect the battery surface for clean and dry monthly. Dirty and wetness may cause leakage of electricity
and descent of voltage.
6.5 Inspect the terminals, inserters, fuse electric component for loose, broken monthly.
6.6 Change the hydraulic oil (L-HM46 Hydraulic oil (equivalent to ISO VG46)) after 20 working hours in the
beginning. Then, change the oil every 300 working hours. If the stacker is not used frequently, please change
the oil every 18 months.
6.7 When changing the oil, put the piston at the lowest position, then open the electric control box, remove the
bolt on the bottom the valve plate and the bolt connecting motor and valve plate, the pump section is disas-
sembled.
6.8 Clean the valve plate and the oil tank, then fill oil to 80% of oil tank content. And inspect the connection to