Please operate the inverter in the following procedure 1 to 6;
1. Check the purchase
Check that the inverter type is the same as your order.
Inverter main unit
Rating label
Danger label
2. Install the inverter
5 cm or more
Inverter
3 cm or more
5 cm or more
Normal installation
* For side-by-side installation,
refer to the instruction manual.
4. Connect to the power supply and the motor (wiring)
(1) Connect to the terminal R, S and T(single phase: R and S) of the power supply.
Power
MCCB
supply
Shorting-bar
* Remove the
shorting-bar
when using DC
reactor (DCL).
All manuals and user guides at all-guides.com
Name plate
3. Remove the terminal block cover
ex. VFS15S-2002PL-W
3 cm or more
1.3.2(1)̲外側端子台カバーはずし方
̲slc̲rev01̲03.eps
For EMC plate
Power circuit terminal block
5
Inverter Type
Inverter rated
output capacity
Power supply
(1) Insert a screwdriver or
other thin object into the
hole indicated with the
mark.
(2) While pressing on the
screwdriver, rotate the
terminal cover downward to
remove it.
(3) Next, remove the inside
terminal block cover.
Motor
(2) Connect to the terminal
U, V and W of the motor.
* Ground must be
connected securely.
Grounding terminal
E6581899
EN
Name plate