1.
INTRODUCTION
In order to guarantee personal protection and avoid any material damage, it is essential to follow
the instructions given in this manual and all other documents supplied with the machine, especially
the manual entitled "Safety regulations"..
1.1.
Specification plate
To facilitate future spare parts ordering and for your own information about vacuum pump, you are advised to
copy the details from the vacuum pump identification plate onto this page when you take delivery of your
machine.
Pump type
Serial number
1.2.
Use
The equipment must be used for the purpose for which it is designed : The pumps described in this manual are
of the oil‐free rotary vane type.
These vacuum pumps have been specifically designed to work with dry, clean air and inert gas, the suction
temperature of which must be between 0°C and 40°C.
Any other use is prohibited. The Manufacturer is not liable for any damage to persons and/or property caused by
improper pump use or uses of the pump which are not allowed.
1.3.
Contraindications
Any use other than that for which the pump was constructed is to be considered an abnormal
condition and therefore can cause damage to the pump and pose a serious danger to the operator.
Below is a series of operations involving improper use of the pump, which are not permitted under any
circumstances.
•
Do not use the pump in an explosive or aggressive atmosphere or in an atmosphere with a high
concentration of dust or oily substances in the air and do not use the pump to pump explosive,
flammable or corrosive gases or gas that form particles. Using the pump in these atmospheres and
with these types of gases can cause injury, explosion, fire or serious damage to the pump.
•
Do not use non‐original spare parts or parts not provided by the manufacturer.
•
Do not use the unit to pump solid materials, chemicals, powders, solvents or other substances
differing from those permitted These types of materials may damage the unit, degrade its
performance or reduce its life.
•
do not expose the pump to rain, steam or excessive humidity.
•
Do not place or store near in the proximity of flammable or combustible materials or substances.
519924.03
ARICA 11‐16‐26‐40‐61‐80‐100
1.4.
Characteristics
Motor power
Flow rate
Final vacuum
(1~ / 3~)
ARICA
m³/h
mbar abs.
kW
50 Hz 60 Hz
50 Hz
60 Hz
11 V / P
10
12
0.37 / 0.37
0.45 / 0.45
16 V / P
16
19
0.66 / 0.55
0.72 / 0.66
26 V / P
25
29
0.75 / 0.75
0.90 / 0.90
40 V / P
40
46
1.5 / 1.5
1.8 / 1.8
61 V / P
60
70
1.5
1.8
80 V / P
80
90
2.2
2.7
100 V / P
100
115
3
3.6
Operating temperature
Outlet
ARICA
Intake pump
(°C) (room temp. 20°C)
pump
50 / 60 Hz
11 V / P
1/2"
1/2"
70 ‐> 75 / 80 ‐> 85
16 V / P
1/2"
1/2"
55 ‐> 60 / 60 ‐> 65
26 V / P
3/4"
1/2"
65 ‐> 70 / 70 ‐> 75
40 V / P
1"
1"
75 ‐> 80 / 80 ‐> 85
61 V / P
1"
1"
70 ‐> 73 / 72 ‐> 75
80 V / P
1"
1"
72 ‐> 78 / 75 ‐> 80
100 V / P
1"1/2
1"1/2
78 ‐> 82 / 80 ‐> 85
Rotation
Maxi Pressure
Noise level
speed
bar
dB(A)
tr/min ‐ rpm
50Hz / 60Hz
50Hz / 60Hz
50Hz / 60Hz
50Hz / 60Hz
120
0.6
1400 / 1700
64 / 66
120
0.6
1400 / 1700
63 / 65
120
0.6
1400 / 1700
65 / 67
120
0.8
1400 / 1700
68 / 70
120
1 / 0.8
1400 / 1700
70 / 72
120
1 / 0.5
1400 / 1700
72 / 74
120
1.5 / 1
1400 / 1700
75 / 77
Required room
Ambient temperature for
temperature for place of
storage/transport (°C)
installation (°C)
0 ‐> 40
0 ‐> 40
0 ‐> 40
0 ‐> 40
0 ‐> 40
0 ‐> 40
0 ‐> 40
Weight
kg
1~ / 3~
15.5 / 14
29.5 / 27.5
29 / 28.5
40 / 37.5
66
71
87
‐20 ‐> 50
‐20 ‐> 50
‐20 ‐> 50
‐20 ‐> 50
‐20 ‐> 50
‐20 ‐> 50
‐20 ‐> 50
7