Troubleshooting by a qualified electrician
Fault
Cause
LED flashes
red
Self-test of the charging station
faulty
Internal fault
LED lights up
red
Overheating, charging interrupted
LED display does
No electrical power supply at the
charging station
not light up
Safety device in the charging station
has tripped
Disassembly, storage and disposal
Disassembly
!
Danger
Fatal shock hazard!
Components are live. Touching live parts will result in electric shock, burns or death. Observe the following points
before working on the electrical system.
• Disconnect the device from the power supply
• Secure against switching back on
• Check freedom from voltage
• Grounding and short circuiting
• Cover adjacent live parts and secure the danger zone
Carry out the disassembly as follows: (in compliance with the five safety rules)
1. Make sure that the electrical power supply is switched off.
2. Disconnect the feeder cable.
3. Disassemble the charging station.
Storage
Storage must be in a clean, dry place.
Disposal
The device must not be disposed of with household waste.
• Please send the defective device back to us. We will handle the professional disposal on your behalf
• If you have any questions, contact your dealer or disposal company
• Dispose of the packaging material in the waste containers for cardboard, paper and plastic
OPERATING INSTRUCTIONS
efuturo Wallbox
Note on troubleshooting
Switch off the charging station, after switching it on
again the fault should be eliminated
Switch off the charging station, after switching it on
again the fault should be eliminated.
Contact your service partner if the fault cannot be
eliminated
Wait until the charging station has cooled down again
Check electrical power supply
Switch on the safety device again