2) Assembly and installation

To install the TCB sensitive edge, proceed as follows:
1. Cut the aluminium profile exactly to size and fix at the envisaged
point; to secure use 4 mm rivets or 3.5 countersunk head screws
taking care to countersink the aluminium profile sufficiently to
house the screw head. Secure at both ends of the profile and at
minimum 30 cm intervals throughout the length.
2. Place the TCB65 sensitive rubber profile on a flat surface, ensure
that it is not bent or twisted, and cut to size as required. The pro-
file length must be 25 mm shorter than length "L" of the finished
sensitive edge (space occupied by terminal caps). The cut must
be clean and burr-free and at perfect right angles to the length;
do not use a hacksaw, but the TCF scissors may be used if nec-
essary.
3. In relation to the outlet hole of the TCS250 connector wire (rear;
right or left), use a screwdriver to make a 3-5 mm hole in the
cable gland on the TCT65 terminal cap
4. Route the wire through the hole made above.
5. On the two ends of the sensitive rubber profile, insert the con-
nector TCS250 with wire on one end and the connector with
8200Ω terminal resistance on the other.
In this initial phase the 2 connectors should be inserted mid-way
and only pressed in fully later on.
!
Ensure that the four pins of the connector are inserted in
the vicinity of the copper wires inside the conductive strips.
All manuals and user guides at all-guides.com
6. Using an Ohmmeter connected on the wire of the TCS250 con-
7. Use the brush to apply the TCP activator on the surfaces of the
8. Apply the TCC adhesive in a circle on the connector only and
9. Prepare the surfaces to be glued by spreading the TCP activator
nector, measure the resistance value of the assembled edge; the
value must be 8200Ω ± 500Ω, while on edge activation the val-
ue must be below 1000Ω. If these resistance values are not
detected, remove the connectors and repeat the insertion proce-
dure described in point 5.
two connectors and the corresponding surfaces of the sensitive
rubber profile.
press it down immediately until the edge of the connector is
touching the border of the sensitive edge.
Repeat the same operations for the second connector.
on the sensitive rubber profile and the terminal caps.
Apply the TCC adhesive on the front and surrounding surfaces of
the sensitive rubber edge. Then place the terminal cap against
the sensitive rubber edge and immediately press the parts down
uniformly until the adhesive starts to act (approx. 20-30 seconds).
Repeat the same operations for the second terminal cap.