Ribimex Ribiland PRPVC751/43F Manual De Instrucciones Y Mantenimiento página 21

Bomba sumergible
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

water heights that trigger starting and stopping of the pump.
7. To adjust the cut-in/cut-out height, fix the float switch cable and adjust the cable to the required
length.
Warning: to dry out premises (cellar draining for example) it will be necessary to place the pump
below floor level.
4.7.2- Blocked float switch (Fig.3)
1. The pump must be in a vertical position: ensure that it is stable during operation.
2. Ensure that the float switch can move freely.
3. The suction holes must never be obstructed. It is therefore preferable that the pump should never be
placed directly on the ground or on the bottom of the well, pond or vessel.
For example, use a brick to support the pump.
4. To operate the pump, press the On/Off switch.
Warning: to dry out premises (cellar draining for example) it will be necessary to place the pump
below floor level.
V. OPERATION
5.1- Intended use
1. This submersible pump can be used for domestic, industrial or farming applications, for pumping
clear water with particles in suspension that are less than 0.2mm in diameter.
2. The pump is fully submersible: the immersion depth must not exceed 15m (refer to
characteristics table).
3. The pump should not be used for sucking up liquids or materials that are corrosive,
combustible/flammable, explosive; or food liquids.
4. The temperature of liquids sucked up should not exceed 35°C.
5. Any other use, other than that described in the instructions, is likely to damage the pump and to
put the user in serious danger.
5.2- Operation
5.2.1- In automatic functioning mode (active floating switch)
Fig.2
Fig.3
Page 21 / 57

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

510941

Tabla de contenido