2.1 CROSS REGULATION
The +5V & +3.3V combined load and +12VDC load shall remain within the defined in section 2.0 over
cross load combinations shown Figure 1:
120.00
100.00
80.00
60.00
40.00
20.00
0.00
0.00
Figure 1
2.2 HOLD-UP TIME: 16ms(minimum)
Test Condition: Full load. AC input 115V or 230V, 47Hz .
2.3 LOAD TRANSIENT RESPONSE (STEP LOAD)
Step load changes up to 60%(12V) and 30%(3.3V and 5V) of full load, while other loads remains
constant within the rating. The load waveform shall be a square wave with the slope of the rise and
fall at 1.0A/usec and the frequency shall be from 50Hz to 10kHz. The DC output voltage will stay
within regulation of ±5% during the step load changes.
2.4 OVERSHOOT
Overshoot at turn on or turn off shall be less than 10% of the nominal output voltage.
03
100.00
200.00
300.00
Cross Regulation
400.00
500.00
Total +12V power (W)
100.00
0.00
0.00
0.00
600.00
700.00
800.00